8.3 Gate Operator’s Monthly Checkup

Caution:

   

Make SURE gate area is clear BEFORE testing the gate operator!

DO NOT

 repair or adjust gate systems yourself. Contact a trained gate systems technician with any questions

or to make any repairs or adjustments. If you feel uncomfortable performing any of these inspections or testing,
a qualified service technician will perform the visual inspections and testing for you.
You can find a trained service technician at DoorKing’s “Dealer Locator” at www.doorking.com

Test Built-In Reversing Sensor

Begin with the gate in the fully 

OPEN

 position. Stand just outside the path of the gate and close the gate (typically auto-timer 

will time-out and close gate automatically). As the gate is 

closing

, firmly press a solid object against the end of the gate 

frame in the direction opposing the travel of the gate. The gate should 

stop

 within 2 sec. and 

reverse

 to the 

OPEN

 position. 

Another input command is needed before the gate will reset and close again. Repeat this test while 

opening

 the gate. Start 

from the fully 

CLOSED

 position. While 

opening

, gate should 

stop

 and 

reverse

 to the 

CLOSE

 position. If gate does 

NOT

 

respond like it should in 

either

 direction of gate travel, contact a trained service technician to make adjustments or repairs.

Test Photo Sensors

If the gate has a photo sensing device protecting the path of a 

closing gate

, perform the following test. Begin with the gate in 

the fully 

OPEN

 position. Stand just outside the path of the gate and close the gate (typically auto-timer will time-out and close 

gate automatically). Pass an object across the path of the closing photo sensing beam. The gate should 

stop

 within 2 sec. 

and 

reverse

 to the 

OPEN

 position. Typically the auto-timer times out and gate closes again.

If the gate has a photo sensing device protecting the path of a 

opening gate

, start from the fully 

CLOSED

 position. 

OPEN

 

gate. Pass an object across the path of the opening photo sensing beam. The gate should 

stop,

 the gate will resume opening 

when the beam is clear. If gate does 

NOT

 respond like it should in 

either

 direction of gate travel, contact a trained service 

technician to make adjustments or repairs.

Test Reversing Edges

If the gate has a reversing edge(s) protecting the path of a 

closing gate

, perform the following test. Begin with the gate in the 

fully 

OPEN

 position. Stand just outside the path of the gate and close the gate. As the gate is closing, firmly press a solid 

object against the reversing edge in the direction opposing the travel of the gate. The gate should 

stop

 within 2 sec. and 

reverse

 to the 

OPEN

 position (typically auto-timer will time-out and close gate automatically). If the gate encounters 

another

 

obstruction before it is closed, the gate will 

stop 

and reverse to the 

OPEN

 position 

again

. A input command is needed before 

the gate will reset and close again, auto-timer will 

NOT

 close gate (Typically, press your remote button for input command).

If the gate has a reversing edge(s) protecting the path of a 

opening gate

, starting from the fully 

CLOSED

 position.

Stand just outside the path of the gate and open the gate. 

OPEN

 gate. As the gate is opening, firmly press a solid object 

against the reversing edge in the direction opposing the travel of the gate. gate should 

stop

 and 

reverse

 to the 

CLOSE

 

position. If gate does 

NOT

 respond like it should in 

either

 direction of gate travel, contact a trained service technician to make 

adjustments or repairs.

Visual Inspection

Visually inspect the rollers, fasteners, brackets and other gate hardware for proper alignment, proper tightness, and signs of 
damage, breakage, looseness, rust or wear. Moving parts should be lubricated and should not be squeaking.
Visually inspect wiring for fraying or exposure. If a malfunction is found, contact a trained service technician to make 
adjustments or repairs.

Note:

 This gate operator uses high levels of force to move the gate and most people underestimate the power of these 

systems and do not realize the potential hazards associated with this system if 

NOT

 maintained properly.

Scheduled maintenance visits are offered by most qualified service technicians to MAINTAIN your gate operator system.

Содержание 9150 Series

Страница 1: ...wh ile gat e is mo vin g Re ad ow ner s ma nua l and saf ety ins tru ctio ns SE RI OU S IN JU RY OR DE AT H CL AS S CE RT IFI ED TO CA N C SA C2 2 2 NO 24 7 CO NF OR MS TO AN SI UL 32 5 VE HI CU LA R...

Страница 2: ...sition Normal Setting Gate fully closes Gate stops short 1 from full close position Used for a reversing edge device Gate stops short 2 from full close position Used for a reversing edge device Gate s...

Страница 3: ...N input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will prevent gate from closing When gate is closing input will stop gate when SW 2 switch 2 is O...

Страница 4: ...e right to make changes in the products described in this manual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc...

Страница 5: ...OF GATE OPERATOR 45 8 1 Alarm Sounding OR Chirping and Gate WILL NOT Operate 8 2 Manual Gate Operation 8 3 Gate Operators Monthly Checkup 8 4 New Installation Checklist for Installer and Property Owne...

Страница 6: ...e to 2 1 4 inches or less Install a contact sensor in this area for safety See on next page and page 26 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object...

Страница 7: ...ns Non Contact Sensors Photo Sensors 1 2 Entrapment protection devices are required to reduce the risk of injury Install sensors where the risk of entrapment or obstruction exists while gate is moving...

Страница 8: ...reduce reversing sensitivity to compensate for a damaged gate For gate operators utilizing Type D protection 1 The gate operator controls must be placed so that the user has full view of the gate area...

Страница 9: ...s are installed a minimum distance of 6 feet away from the gate and gate operator or in such a way that a person cannot touch the gate or gate operator while using the device If access control devices...

Страница 10: ...Inherent entrapment protection system Type B1 Non contact sensor photoelectric sensor or the equivalent Type B2 Contact sensor edge device or equivalent Type C Inherent force limiting inherent adjust...

Страница 11: ...for vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that control...

Страница 12: ...ops Gate End Retainer Helps stabilize the end of the gate in the open or closed position Recommended for all slide gate applications Endless Idler Assembly with Protective Cover Helps to minimize a pi...

Страница 13: ...CSA C22 2 NO 247 CONFORMS TO ANSI UL 325 VEHICULAR GATE OPERATOR HP 53382 MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing Inc Inglewood CA WARN ING MOVING GATE CAN CAUSE Operate gate only w...

Страница 14: ...l stop for the gate Both are shown only one type is needed Base Plate Stop Bracket Chain Setup Chain Setup The Model 9150 operator is designed to be installed in the front rear center or ceiling mount...

Страница 15: ...oorKing Rear Position with Concrete Pad Hides the chain from outside the property looking in Chain setup is the same as above Rear Position with Post Mount Hides the chain from outside the property lo...

Страница 16: ...roperty looking in Optional chain tray kit can be used and is recommended for gates over 20 ft supports the chain s weight and helps prevent chain stretching See page 17 for more information Note Chai...

Страница 17: ...r and Communication wires Loop Lead In Wires Low Voltage wire insulation AC Input Power High Voltage wire insulation AC Input Power High Voltage wire insulation 3 4 Inch Conduit Recommended The condui...

Страница 18: ...e Weld the posts to the base plate and mount assembly into concrete BEFORE attaching the operator Conduit runs up through 6 x 6 steel posts Note Operator must be mounted 1 min away from gate Low Volt...

Страница 19: ...et Lines up with Idler Wheels Correct Chain Bracket Height Correct Chain Bracket Height Chain brackets positioned too low NO NO NO NO Chain Idler Wheels 1 minimum from operator housing to gate YES YES...

Страница 20: ...wheel wear and chain stretching Lower chain MUST align with upper chain Upper and lower chain MUST be the same height as they are on the operator idler wheels NO NO NO Gate Rail Gate Rail Chain Bracke...

Страница 21: ...he chain DoorKing offers a chain tray kit in sections to fit any length gate DoorKing P N 2601 270 10 Ft section Chain Tray Supporting Bracket Facing down Chain Tray Supporting Bracket Facing up Weep...

Страница 22: ...han the maximum distance shown it is recommended that a service feeder be installed When large gauge wire is used a separate junction box must be installed for the operator connection The wire table i...

Страница 23: ...e with local codes Be sure to color code all wiring It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges an...

Страница 24: ...Detector Single Channel Loop Detector Dry Relay Contact N C N O Set the DIP switches on the circuit board to the desired setting See switch setting charts on next 2 pages DIP Switches ON 1 2 3 4 5 6 7...

Страница 25: ...g on a green light when the gate is full open If a magnetic lock is used with the gate operator these switches must be set for magnetic lock operation which limits the relay to activate only when the...

Страница 26: ...orized entry If switch 2 is turned OFF Reverse the closing gate that gets activated by a tailgating vehicle will reverse back to the open position possibly allowing the tailgating vehicle unauthorized...

Страница 27: ...powered up the first open command will automatically run Multiple gate cycles that will locate and remember the gate s open and close positions These positions are determined by the physical stops th...

Страница 28: ...est the operator reversing sensitivity Press the Key Switch button to cycle the gate While gate is cycling slowly rotate reverse sensor clockwise until the gate reverses direction Rotate reverse senso...

Страница 29: ...ov ing Read own er s man ual and safet y instr uctio ns SER IOU S INJ UR Y OR DE ATH CLA SS CER TIFI ED TO CAN CSA C22 2 NO 247 CON FOR MS TO ANS I UL 325 VEH ICU LAR GAT E OPE RAT OR HP 53382 MOD EL...

Страница 30: ...am 3 OPEN Edge 4 CLOSE Edge Only 1 monitored Device can be connected to each input An OPTIONAL Expansion Kit sold separately will allow connection for additional devices 1 OPEN Beam Switch 1 2 Ground...

Страница 31: ...ged into the built in convenience outlets located on the operator See page 25 See pages 2 and 26 for gate gap area and filler post information Open Beam Receiver MUST monitor for the presence of the t...

Страница 32: ...PE LEARN INPUT OUTPUT ASSIGNMENTS ON 1 2 3 4 5 6 A B X X 3 4 5 6 Model MIM 62 Class 2 Device Set to R Set 3 to A Output Set 4 to OFF See manufacturer s manual to LEARN open edges See manufacturer s ma...

Страница 33: ...E Beam 3 OPEN Edge 4 CLOSE Edge DIP switches MUST be turned ON for each device wired to terminal Wire Mesh CLOSE Beam photocell CLOSE Beam photocell A wide gate will not be protected from obstructions...

Страница 34: ...ns the gate for exiting vehicles without having to use a transmitter or keypad The exit loop can be placed a minimum of 4 feet away from the reverse loop or far enough away from the gate so the gate h...

Страница 35: ...ON input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will prevent gate from closing When gate is closing input will stop gate when SW 2 switch 2 is...

Страница 36: ...to the partial open 14 ft setting External entrapment protection devices will also open the gate to the partial open setting If the Inherent Reverse Sensor gets activated during the close cycle it wil...

Страница 37: ...nputs loop detector problems any forced entry attempts if the gate has struck anything during the open or close cycle power interruptions etc For more detailed information refer to the Tracker Install...

Страница 38: ...wired in parallel between primary and secondary operators SW 2 switch 1 must be OFF Plug into Primary Operator Exit Loop Port Dual Channel 9409 Automatic Exit Loop Reverse Loop Reverse Loop LL OPE LL...

Страница 39: ...with a rigid object or stop or reverse when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate...

Страница 40: ...gate will reverse and run back to the closed position The time clock input is still present but the gate will not re open Example 2 If the gate is closing and an entrapment protection device is activa...

Страница 41: ...D that power to the operator has been SHUT OFF Solenoid Lock Clutch Plate SW 2 switch 4 must be OFF ON 1 2 3 4 5 6 7 8 SW 2 Note DoorKing operators have a built in alarm reset push button mounted on t...

Страница 42: ...bs truc tion s Do not allow child ren to play in gate area or ope rate gate Do not stan d in gate path or walk thro ugh path whil e gate is mov ing Rea d own er s man ual and safe ty inst ruct ions SE...

Страница 43: ...hen an obstruction is encountered Check for alignment tightness and wear Check vehicular exit and reverse loops for proper operation Check manual release for proper operation See page 46 Pulleys Check...

Страница 44: ...gh voltage supply A voltage drop on the supply line usually caused by using too small supply voltage wires will cause the operator to malfunction Refer to the wire size chart in section 2 1 on page 18...

Страница 45: ...om excess wires can diminish magnetic field Check that the magnetic pickup transistors on control board are within 1 8 inch of the clear plastic protective cover above the black plastic magnetic sprin...

Страница 46: ...ntains all the necessary wires to interconnect primary secondary operators Cable length 30 ft P N 2600 755 40 ft P N 2600 756 50 ft P N 2600 757 Time Clock 7 day time clock can be used to automaticall...

Страница 47: ...6 5 4 3 2 1 Brown White White Green Black Black White White Black White White Loop Yellow Red Red Yellow White Chassis Ground Board Ground Convenience Outlets Power Neutral Model 9150 1 2 HP 115 VAC...

Страница 48: ...ellow White Reset Button AC Power Switch MOV Assembly Brown White White Green Black Black White White Black Red Yellow White Chassis Ground Board Ground Convenience Outlets Motor Resistors Power Neutr...

Страница 49: ...mpletes the reverse cycle the inherent entrapment protection system Type A gets activated If a Fire Dept Access Device has been activated by emergency personnel then operator can be reset and put back...

Страница 50: ...ONS for more information about operating this gate operator Gate CANNOT be manually PUSHED open until FAIL SECURE Lock has been UNLOCKED WARNIN G MOV IN G GA TE CA N CA US E Ope rate gat e onl y whe n...

Страница 51: ...the gate will resume opening when the beam is clear If gate does NOT respond like it should in either direction of gate travel contact a trained service technician to make adjustments or repairs Test...

Страница 52: ...installer AND property owner If it is not applicable enter N A Please note that the checklist is intended to be a summary of many important automated vehicular gate aspects But may not inclusively id...

Страница 53: ...STRUCTIONS for more information about operating this gate operator When Alarm is Sounding OR Chirping Operator is in a HARD Shutdown Condition The alarm will sound for 5 five minutes After five minute...

Страница 54: ...25 August 2018 Standard Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists The operator will NOT run without one or more monitored type B1 or...

Отзывы: