7.1 Maintenance
SECTION 7 - MAINTENANCE AND TROUBLESHOOTING
When servicing the gate operator, always check any secondary
(external) reversing devices (loops, photocells, etc.) for proper
operation. If external reversing devices cannot be made operable,
do not place this operator in service until the malfunction can be
identified and corrected.
Always check the inherent reversing system when performing any
maintenance. If the inherent reversing system cannot be made
operable, remove this operator from service until the cause of the
malfunction is identified and corrected. Keeping this operator in
service when the inherent reversing system is malfunctioning
creates a hazard for persons which can result in serious injury or
death should they become entrapped in the gate.
When servicing this gate operator, always turn power
OFF!!
Operator
Component
Maintenance
Monthly Interval
6
1
12
Alarm
Chain
Drive Belt
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Fire Dept.
Gate
Loop(s)
Manual Release
Inherent Reverse System
Entrapment Protection
Devices
Complete System
Activate the primary (inherent) reverse system by blocking the
gate with a solid object. When the gate reverses, block the gate
in the opposite direction prior to the limit being reached. The
entrapment alarm should activate. Press the reset button to
silence the alarm.
Check for sagging. Tighten if necessary.
Clutch
Check for proper slippage when an obstruction is encountered.
Check for alignment, tightness and wear.
Check vehicular exit and reverse loops for proper operation.
Check manual release for proper operation. See page 46.
Pulleys
Check for alignment. Check set screws.
Complete check of gate and gate operating system.
Check emergency vehicle access device for proper operation.
Grease
Wheels and guide rollers if necessary.
Inspect for damage. Check gate wheels, rollers and guides for
wear and grease if necessary.
Check that the gate reverses on contact with an object in both
the opening and closing cycles. See page 47.
Adjust the reversing sensor and/or clutch if necessary.
Check external protection devices stop or reverse the gate when
activated. See page 47.
✓
✓
Align clutch plate
holes with screws to
repair solenoid lock.
DO NOT
remove clutch
plate.
Remov
e
Pulley Assembly
Every time
the 9150 is powered up, the
First
open command
will automatically run “
Multiple gate cycles”
that will locate and
remember the gate’s open and close positions (See page 23).
Batteries
If operator is equipped with optional DC open system, check the
batteries for any leakage or loose connections. Batteries should
be replaced every two years.
✓
Warning Signs
Check that warning signs are on
BOTH
sides of the gate area.
Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is
observed or suspected. High cycle usage may require more frequent service checks. Contact servicing dealer. If you don’t
know your servicing dealer, see DoorKing’s “DEALER LOCATOR” at www.DoorKing.com