59
59
59
59
C
C
C
Compo
ompo
ompo
omponents
nents
nents
nents of
of
of
of Fusion Hybrid Gas Conde
Fusion Hybrid Gas Conde
Fusion Hybrid Gas Conde
Fusion Hybrid Gas Condens
ns
ns
ns module
module
module
module
V:
V:
V:
V:
Fan.
BC:
BC:
BC:
BC:
Circulation pump.
C:
C:
C:
C:
Module ground connection.
EI:
EI:
EI:
EI:
Ionisation electrode.
PWM
PWM
PWM
PWM
V
V
V
V
::::
Fan PWM cable.
Sp:
Sp:
Sp:
Sp:
Water pressure sensor.
Sc:
Sc:
Sc:
Sc:
Heating sensor.
EV:
EV:
EV:
EV:
Gas valve..
Sr:
Sr:
Sr:
Sr:
Return sensor.
Sh:
Sh:
Sh:
Sh:
Flue gas sensor.
TS:
TS:
TS:
TS:
Safety thermostat.
P
P
P
PWM
WM
WM
WM
BC
BC
BC
BC
: : : :
PWM cable for circulation pump.
V3V G1:
V3V G1:
V3V G1:
V3V G1:
Heating/DHW 3-way valve.
V3V G1´:
V3V G1´:
V3V G1´:
V3V G1´: : : : :
Heating/DHW 3-way valve.
V3V E1:
V3V E1:
V3V E1:
V3V E1:
Heating/DHW supporting 3-way valve.
Tacs:
Tacs:
Tacs:
Tacs:
DHW storage tank thermostat.
R:
R:
R:
R:
Relay.
Sel ACS:
Sel ACS:
Sel ACS:
Sel ACS:
DHW selector.
Sel CAL:
Sel CAL:
Sel CAL:
Sel CAL:
Heating selector.
Con
Con
Con
Conn
n
n
ne
ee
ecti
cti
cti
ctions in module
ons in module
ons in module
ons in module
F:
F:
F:
F:
Live.
N:
N:
N:
N:
Neutral.
TAF:
TAF:
TAF:
TAF:
Cooling Room Thermostat.
TAC:
TAC:
TAC:
TAC:
Heating Room Thermostat.
Con
Con
Con
Conn
n
n
ne
ee
ections in module
ctions in module
ctions in module
ctions in module,,,, between
between
between
between module and
module and
module and
module and Dual Clima
Dual Clima
Dual Clima
Dual Clima heat pump
heat pump
heat pump
heat pump::::
L:
L:
L:
L:
Heat Pump Live Wire.
G1S:
G1S:
G1S:
G1S:
Heat Pump “G1S” connection.
N:
N:
N:
N:
Heat PUmp Neutral.
E1L:
E1L:
E1L:
E1L:
“E1L” connection of heat pump. DHW
supporting connection.
E1N:
E1N:
E1N:
E1N:
“E1N” connection of heat pump. DHW
supporting connection.
E2L:
E2L:
E2L:
E2L:
“E1L” connection of heat pump. Heating
supporting connection.
E2N:
E2N:
E2N:
E2N:
“E2N” connection of heat pump. Heating
supporting connection.
IN
IN
IN
IN1
11
1: : : :
Input signal from the DHW probe to the
heat pump.
Sacs (BC):
Sacs (BC):
Sacs (BC):
Sacs (BC):
DHW temperature probe .
C:
C:
C:
C:
“C” connection in heat pump. Input signal
from the cooling room thermostat to the heat
pump.
H:
H:
H:
H:
“H” connection in heat pump. Input signal
from the heating room thermostat to the heat
pump.
COM:
COM:
COM:
COM:
“COM” connection in heat pump. Input
signal from the common room thermostats to
the heat pump.
C4L (IN): “C4L” connection in heat pump. Input
signal of support circulation pump.
N(C4) (IN): “N” connection in heat pump. Input
signal of support circulation pump.
C4L (OUT): Support pump connection.
N(C4) (OUT): Support pump connection.