The module electrical connections must be made by sufficiently qualified staff in strict compliance
with the sections below and with any electrical safety regulations applicable at time of installation.
DANGER
DANGER
DANGER
DANGER
It must be ensured that the module is disconnected from the electrical supply before carrying
out any servicing inside the module and, particularly, on the electric terminal strips.
If the electrical supply is connected electrical contact could occur, causing serious damage
and/or death due to electrocution.
The module is designed for mains connection at 230 V - 50 Hz using its standard supplied cable.
Make sure that the electrical installation corresponds to the maximum power to be supplied, as
indicated on the module's specifications label. To replace the main fuse on the electronic card, use
2A fuses.
It is e
It is e
It is e
It is essenti
ssenti
ssenti
ssentiaaaal for the
l for the
l for the
l for the module
module
module
module to be groun
to be groun
to be groun
to be grounded
ded
ded
ded....
M
M
M
Make su
ake su
ake su
ake sure you have tightened the ca
re you have tightened the ca
re you have tightened the ca
re you have tightened the cab
b
b
bles
les
les
les sufficie
sufficie
sufficie
sufficiently.
ntly.
ntly.
ntly. T
TT
The
he
he
he module
module
module
module eeeelect
lect
lect
lectrical
rical
rical
rical
cccconnections
onnections
onnections
onnections mu
mu
mu
must be made in compliance with th
st be made in compliance with th
st be made in compliance with th
st be made in compliance with the applicab
e applicab
e applicab
e applicable standard
le standard
le standard
le standards and r
s and r
s and r
s and regulations in t
egulations in t
egulations in t
egulations in th
h
h
he
e
e
e
p
p
p
plac
lac
lac
lace of install
e of install
e of install
e of installati
ati
ati
atio
o
o
on
n
n
n
....
6.6
6.6
6.6
6.6
Start
Start
Start
Start----up
up
up
up
In order for the
w
w
w
waaaarranty to be valid
rranty to be valid
rranty to be valid
rranty to be valid
, the module must be started up by an official
DOMUSA
DOMUSA
DOMUSA
DOMUSA
T
TT
TEKN
EKN
EKN
EKNIK Techni
IK Techni
IK Techni
IK Technical As
cal As
cal As
cal Asssssistance Ser
istance Ser
istance Ser
istance Servic
vic
vic
vice
ee
e
. Before the start-up process, the followings must be complied
with:
- The module must be connected to the mains.
- The installation must be filled with water (the pressure must be between 0.1 and 0.15 MPa (1 to
1.5 bar)).
- Check the flue is correctly installed.
- Check the gas supply is correctly installed.
- Drain the air from the module gas circuit, opening the gas installation shut-off valve and
slightly loosening the valve gas intake pressure port for a moment, as otherwise the air would
have to come out gradually through the burner.
- If the installation has flow and return valves, check they are open.
- If chronothermostat or remote control is available, set it to the desired temperature.
- It is essential to carry out a module combustion analysis, using a suitable analyser for this
purpose. The combustion analysis will be carried out in the collection of gas samples from the
gas outlet. If the analysis shows the combustion is outside the limits indicated in the
"Adjusting
the combustion"
section, adjust the module combustion.
To start up the module, follow the instructions in
“Switching on the module”
section.
6.7
6.7
6.7
6.7
Insta
Insta
Insta
Installation hand
llation hand
llation hand
llation hand----over
over
over
over
After the initial start-up, the Technical Assistance Service will explain to the user how the module
functions, making any observations they consider relevant.
The installer is responsible for clearly explaining to the user the functioning of any control or