ADDITIONAL FUNCTIONS
ADDITIONAL FUNCTIONS
ADDITIONAL FUNCTIONS
ADDITIONAL FUNCTIONS
The
Fusio
Fusio
Fusio
Fusion Hybrid Gas Condens
n Hybrid Gas Condens
n Hybrid Gas Condens
n Hybrid Gas Condens
module includes the following additional control functions:
12.1
12.1
12.1
12.1
Burner
Burner
Burner
Burner anti
anti
anti
anti----cy
cy
cy
cycling functioning
cling functioning
cling functioning
cling functioning
Parameter
P0
P0
P0
P05
55
5
is used to adjust the minimum interval between burner start-ups. It is used in
installations with very low thermal inertia, to prevent excessively consecutive burner ignition and
extinction cycles, ensuring smoother burner functioning and avoiding premature wear to the
burner components.
12.2
12.2
12.2
12.2
P
P
P
Pump anti
ump anti
ump anti
ump anti----block function
block function
block function
block function
This function prevents the module circulation pumps from seizing up if they have been out of use
for a long period. This system remains enabled while the module is plugged into the mains.
12.3
12.3
12.3
12.3
Anti
Anti
Anti
Anti----fro
fro
fro
frost function
st function
st function
st function
This function protects the module from freezing up during cold weather. The circulation pump will
be activated when the module temperature drops below 7ºC. If the module temperature continues
to drop and reaches 5 ºC, the burner will start up, heating the installation. This system remains on
standby while the module is plugged into the mains. The activation temperature of the anti-frost
protection can be modified through parameter
P38
P38
P38
P38
..
During SHORT periods of absence, particularly in winter and in areas with a high risk of freezing
weather, it is recommended NOT to disconnect the module from the electrical mains or the gas
supply, in order to keep the anti-frost function active and prevent possible bursts due to the water
in the pipes freezing.
12.4
12.4
12.4
12.4
Child protection
Child protection
Child protection
Child protection
When this function is activated, the buttons are locked after 2 minutes have elapsed since their last
use. When this function is enabled through parameter
P24
P24
P24
P24
, the settings of the module can not be
modified. The lock is deactivated by holding the
MODE
MODE
MODE
MODE
button until the cycle has finished.
P24 = 0:
P24 = 0:
P24 = 0:
P24 = 0:
Child protection disabled
P24
P24
P24
P24 =
=
=
= 1:
1:
1:
1:
Child protection enabled
12.5
12.5
12.5
12.5
Module
Module
Module
Module press
press
press
pressure sensor function
ure sensor function
ure sensor function
ure sensor function
This function prevents module failure caused by a low water level and/or excess pressure in the
module. The pressure is detected by a pressure sensor, and its value is displayed on the digital
display (
49. Digita
49. Digita
49. Digita
49. Digital p
l p
l p
l prrrressure gauge
essure gauge
essure gauge
essure gauge
)
. . . .
If the pressure drops below 0.05 MPa (0.5 bar), the electronic
control switches off for the module and triggers an alarm on the display (
"E02"
"E02"
"E02"
"E02"
). If the module
pressure exceeds than 0.27 MPa (2.7 bar), an alarm is triggered on the display (
""""E03"
E03"
E03"
E03"
), warning of
excess pressure. In this case, it is advisable to contact the nearest
Technical Assistance
Technical Assistance
Technical Assistance
Technical Assistance Servic
Servic
Servic
Service
ee
e
and
proceed to emptying the module until the pressure is between 0.1 and 0.15 MPa (1 and 1.5 bar).
Содержание Fusion Hybrid Gas Condens