25
25
25
25
6
66
6
STARTING UP THE BO
STARTING UP THE BO
STARTING UP THE BO
STARTING UP THE BOILER
ILER
ILER
ILER
6.1
6.1
6.1
6.1
Prior warning
Prior warning
Prior warning
Prior warningssss
Repair and maintenance of the module must be carried out by a qualified professional, authorised
by
DO
DO
DO
DOMUSA
MUSA
MUSA
MUSA TEKNIK
TEKNIK
TEKNIK
TEKNIK
. For optimum functioning and conservation of the boiler, it should be serviced
annually.
Please carefully read this instruction manual and keep it in a safe, easily-accessible place.
Before any servicing, disconnect the boiler from the mains and cut off the gas supply. Any
manipulation of the sealed parts of the boiler is prohibited.
DOMUSA TE
DOMUSA TE
DOMUSA TE
DOMUSA TEKNIK
KNIK
KNIK
KNIK
will not be liable for any damages caused by failure to follow these instructions.
6.2
6.2
6.2
6.2
Fill
Fill
Fill
Filling
ing
ing
ing the domestic hot water tank
the domestic hot water tank
the domestic hot water tank
the domestic hot water tank
The hot water tank must be filled before filling the heating circuit. Open the flow of domestic hot
water to the hot water tank, and turn on a hot water tap in the installation. When the tap begins to
run freely, turn it off, as this means the hot water tank is full.
6.3
6.3
6.3
6.3
Filling the heating
Filling the heating
Filling the heating
Filling the heating circ
circ
circ
circuit
uit
uit
uit
The
Fusi
Fusi
Fusi
Fusion Hyb
on Hyb
on Hyb
on Hybrrrrid Gas Cond
id Gas Cond
id Gas Cond
id Gas Condens
ens
ens
ens
module is equipped with a filling disconnector. The heat pump
(external unit) includes a manual drain valve on the upper part of the heat exchanger flow tube
(condenser). Open it during the filling process and wait for the water to start running (please refer
to the operations manual of the
DUAL CLIMA
DUAL CLIMA
DUAL CLIMA
DUAL CLIMA
heat pump). The air should also be bled from the rest
of the installation using the air bleed valves provided. The filling must be carried out slowly,
thereby facilitating air evacuation from the water circuit. Once the installation is full, close the
disconnector valves.
The
Fusion Hybrid Gas Condens
Fusion Hybrid Gas Condens
Fusion Hybrid Gas Condens
Fusion Hybrid Gas Condens
module have a pressure sensor for controlling the pressure of the
installation. If it drops below 0.05 MPa (0.5 bar), a low pressure alarm ("
E02
E02
E02
E02
") will appear on the
display.").
: : : : Turning
Turning
Turning
Turning on the module or the heat
on the module or the heat
on the module or the heat
on the module or the heat pump with
pump with
pump with
pump without water may cause serious damag
out water may cause serious damag
out water may cause serious damag
out water may cause serious damage to
e to
e to
e to
the equipment
the equipment
the equipment
the equipment....
6.4
6.4
6.4
6.4
Gas
Gas
Gas
Gas co
co
co
con
n
n
nnection
nection
nection
nection
For the installation of any type of gas, the installer must be authorised by the Ministry of Industry
and strictly follow the applicable Gas Regulations. The gas installation must comply with the Gas
Installation Regulation (RIGLO).
However, the following recommendations must be complied with, at the least:
- Before installing the gas pipes, check the type of gas is compatible with the boiler.
- Check that the gas meter in the home can measure the rate of gas supply required.
- The gas pipe diameter is not determined by the boiler connection. It should be calculated in
accordance with its length and consequently its pressure drop.
- The pipes must be directly connected to the main gas supply pipe, not connected in parallel to
other gas appliances.
- Check there are no leaks from the installation.
- The gas supply company is the sole responsible for connecting the gas meter to the gas