Room thermostat connection
Room thermostat connection
Room thermostat connection
Room thermostat connection
The boiler has two terminal strips,
TA
TA
TA
TA
1
11
1
and
TA
TA
TA
TA
2
22
2
, for connecting room thermostats or room
chronothermostats (J5 and J7, see "
Electrical Connection Diagram
”). This allows the heating mode
for each circuit installed to be switched off according to the room temperature. To suitably connect
them, first remove the bridge joining the terminals of terminal strip
TA
TA
TA
TA
1
11
1
, and to connect
TA
TA
TA
TA
2
22
2
, simply
connect the thermostat to the terminal strip
Installing a room thermostat will optimise the installation’s performance, adapting the heating to
the requirements of your home and obtaining enhanced comfort. Also, if the thermostat allows the
hours of functioning to be programmed (chronothermostat), it can adapt the heating system to the
hours of use of the installation.
9.6
9.6
9.6
9.6
Anti
Anti
Anti
Anti----legionella function (optiona
legionella function (optiona
legionella function (optiona
legionella function (optional) (with hot water tan
l) (with hot water tan
l) (with hot water tan
l) (with hot water tank only
k only
k only
k only))))
This optional function prevents the bacteria causing legionnaire’s disease from proliferating in the
hot water accumulated in the tank. Every 7 days, the temperature of the water in the tank is raised
to 70 ºC to kill any such bacteria. This function will only run if the boiler is left switched on.
The boiler is supplied with this function disabled. To enable it, carefully read the "
Installation
Instructions
" section. We recommend that the operation for enabling this function is carried out by
qualified personnel.
9.7
9.7
9.7
9.7
Keypad block function
Keypad block function
Keypad block function
Keypad block function
This function protects the control panel from being accidentally or erroneously pressed while it is
being cleaned, by children or by unauthorised persons. When this function is enabled, the
electronic control will not react when any of the symbols or touch buttons on the control panel are
pressed.
To lock the keypad, keep your finger on the RESET touch button
for 5 seconds. The word "
LOC
LOC
LOC
LOC
" will flash on the display until the
control panel is unlocked again.
To unlock the keypad, place your finger on the RESET touch button
again for 5 seconds. The display will then return to its normal
status.