COMBUSTION PRODUCTS
COMBUSTION PRODUCTS
COMBUSTION PRODUCTS
COMBUSTION PRODUCTS EXHAUSTION
EXHAUSTION
EXHAUSTION
EXHAUSTION
4.1
4.1
4.1
4.1
Combustion product exhaust (with air intake from the premi
Combustion product exhaust (with air intake from the premi
Combustion product exhaust (with air intake from the premi
Combustion product exhaust (with air intake from the premises
ses
ses
ses))))....
In this type of exhaust of the combustion products, the air intake is carried out from the place
where the boiler is installed.
The maximum duct length
The maximum duct length
The maximum duct length
The maximum duct length
that can be installed is 12 meters in the Minny 20 model and 10 meters
in the Minny 30 model. For each horizontal meter, the available length is reduced by 2 meters and,
for each 90º elbow, or two 45º elbows, it is reduced by 1 m.
It is recommended that the flue gases outlet pipe be fitted slightly upwardly-inclined 2º to 3º thus
preventing water and condensate projections from being ejected outside.
Horizontal output kit 1m
∅
80
Stainless steel
Cod. CGAS000141
90º Bend
∅
80 Code
Stainless steel
Cod.CGAS000147
45º Bend
∅
80 Code
Stainless steel Cod.
CGAS000148
1m Duct
∅
80 Code
Stainless steel
Cod. CGAS000145
0,5 m Duct
∅
80 Code
Stainless steel
Cod. CGAS000146
Deflector for horizontal output
∅
80
Stainless steel
Cod. CGAS000150
Examples of installation: