A remote control (E20) may optionally be supplied together with the Minny boiler. This remote control
can be used to fully operate the boiler from any room in the home it is installed in. The E20 remote
control governs the settings of heating circuit Nº1 and the installation’s domestic hot water
production (where the case may be).
This remote control allows the hours of home comfort to be programmed for heating circuit Nº1,
adjusting the installation to the particular requirements of the home by measuring the room
temperature and consequently adapting the installation temperature. The remote control can also be
used to adjust the DHW and heating setpoint temperatures at any time, and for viewing the different
boiler operation settings. It also warns of any functioning anomalies affecting the boiler.
The E20 remote control may optionally be connected to an external sensor, for measuring the outside
temperature. When this option is installed, the remote control can adjust the home comfort level
(circuit 1) according to the weather conditions at each particular time, optimising fuel consumption
and heating comfort in the home.
The E20 remote control takes over the control of the boiler when it is connected to it. The different
selectable boiler temperatures must be modified using the remote control. It is easy to install, only
requiring 2 wires for communication between the boiler and the E20 control. It is connected to the
boiler by connecting the two wires on terminal strip
J4
J4
J4
J4
(see “Electrical Connection Diagram”). For
correct installation and functioning, carefully read the instructions enclosed with the remote control.
The following sections contain a general explanation of the E20 remote control’s different operating
modes and options.
10.1
10.1
10.1
10.1
Functioning without an outdoor sensor
Functioning without an outdoor sensor
Functioning without an outdoor sensor
Functioning without an outdoor sensor
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit))))
The maximum temperature for heating circuit Nº1, the scheduled heating times and the desired
room temperatures can be selected on the remote control. The E20 remote control will calculate
the boiler temperature required at each particular time, depending on the temperature of the
room, and it will activate or disable the heating mode of circuit 1 depending on the heating
times and room temperatures programmed.
10.2
10.2
10.2
10.2
Functioning with an external sen
Functioning with an external sen
Functioning with an external sen
Functioning with an external sensor (Optional
sor (Optional
sor (Optional
sor (Optional))))
If the E20 remote control is fitted with an outdoor temperature sensor, it can calculate the heating
temperature of heating circuit 1 according to the outside weather conditions at each particular
time, with optimum adjustment of the heating installation conditions for improved comfort in the
home and energy savings.
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit
Conventional heating installation (direct circuit))))
The maximum temperature, an operating curve for heating circuit Nº1 (see instructions enclosed
with the E20 remote control) and the desired heating times and room temperatures can all be
selected on the remote control. The E20 remote control calculates the required boiler
temperature at each particular time, depending on the temperature inside the home and the
outside weather conditions, in accordance with the operating curve selected (setting
HEATSLOPE 1 on the E20), switching the heating on and off in accordance with the heating
times and the room temperatures programmed.
10.3
10.3
10.3
10.3
Function
Function
Function
Functioning with a DHW tank (Optional
ing with a DHW tank (Optional
ing with a DHW tank (Optional
ing with a DHW tank (Optional))))
When the boiler is installed with a DHW production tank connected, the E20 remote control can be
used to select up to two DHW temperatures and the desired DHW production times. The E20