USER’S INFORMATION MANUAL

CATALOG NO. 3400.581A 

    Effective: 05-15-18   

Replaces: 10-18-17  

         P/N 241716 Rev. 2

WHAT TO DO IF YOU SMELL GAS:

  •     Do not try to light any appliance.

  •     Do not touch any electrical switch; do  

 

not use any phone in your building.

  •     Immediately call your gas supplier    

 

from a neighbor’s phone. Follow the   

 

gas supplier’s instructions.

  •     If you cannot reach your gas supplier,  

 

call the fire department.

Do not store or use gasoline or other flammable 

vapors and liquids or other combustible 

materials in the vicinity of this or any other 

appliance. To do so may result in an explosion 

or fire.

Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNING: If the information in this manual 

is not followed exactly, a fire or explosion 

may result causing property damage, personal 

injury or loss of life.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE 

GAZ:

•   Ne pas tenter d’allumer d’appareils.

•   Ne touchez à aucun interrupteur. Ne pas 

vous servir des téléphones dansle bâtiment 

où vous vous trouvez.

•   Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions 

du fournisseur.

•   Si vous ne pouvez rejoindre le fournisseur 

de gaz, appelez le sservice des incendies.

Ne pas entreposer ni utiliser d’essence ni 

d’autres vapeurs ou liquides inflammables dans 

le voisinage de cet appareil ou de tout autre 

appareil.

L’installation et l’entretien doivent être assurés 

par un installateur ou un service d’entretien 

qualifié ou par le fournisseur de gaz.

AVERTISSEMENT: Assurez-vous de bien suivres 

les instructions données dans cette notice 

pour réduire au minimum le risque d’incendie 

ou d’explosion ou pour éviter tout dommage 

matériel, toute blessure ou la mort.

Models 

0856 - 3006 

Type H

Summary of Contents for XVers 856-3006

Page 1: ...e or explosion may result causing property damage personal injury or loss of life QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez à aucun interrupteur Ne pas vous servir des téléphones dansle bâtiment où vous vous trouvez Appelez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fou...

Page 2: ...r water A AWARNING To minimize the possibility of improper operation serious personal injury fire or damage to the heater Always keep the area around the heater free of combustible materials gasoline and other flammable liquids and vapors Heater should never be covered or have any blockage to the flow of fresh air to the heater CAUTION This boiler requires forced water circulation when the burner ...

Page 3: ......

Page 4: ...E MISE EN MARCHE 1 ARRÊTEZ Lisez les instructions de sécurité sur la portion supérieure de cette étiquette 2 Réglez le thermostat à la température la plus basse 3 Coupez l alimentation électrique de l appareil 4 Cet appareil ne comporte pas de veilleuse Il est muni d un dispositif d allumage qui allume automa tique ment le brûleur Ne tentez pas d allumer le brûleur manuellement 5 Enlever le pannea...

Page 5: ...NT OF HEATER GAS VALVE GAS TRAIN HEAT EXCHANGER T P GAUGE FLOW SWITCH GAS SUPPLY CONNECTION WATER OUTLET 3 FLANGE FLOW SENSOR WATER INLET 3 FLANGE OPTIONAL LOW GAS PRESSURE SWITCH VENT TEMP SENSOR LOW WATER PROBE HIGH GAS PRESSURE SWITCH OPTIONAL ON MODELS 0856 2506 GAS SHUTTER PIM HIGH VOLTAGE SWITCH VERSA BOARD 3 POSITION LOW VOLTAGE SWITCH TOUCHSCREEN DISPLAY LOW VOLTAGE FIELD CONNECTION AIR FI...

Page 6: ...ing procedures are recommended and are good practice for all XVers installations Daily 1 Check gauges monitors and indicators 2 Check instrument and equipment settings See Post Start Up Check in the I O Manual MAINTENANCE Suggested Minimum Maintenance Schedule Regular service by a qualified service agency and maintenance must be performed to ensure maximum operating efficiency Maintenance as outli...

Page 7: ...me sensor 4 Conduct a combustion test at high and low fire Carbon dioxide should be 8 6 to 9 4 at full fire for natural gas and between 9 9 to 10 7 for pro pane gas Carbon monoxide should be 100 ppm 5 Check valve coil for 60 cycle hum or buzz Check for leaks at all valve fittings using a soapy water solution while boiler is operating Test other oper ating parts of all safety shut off and control v...

Page 8: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...