EN
42
DUAL CLIMA R
NOTE: Days of the week: MO (Monday), TU (Tuesday), WE (Wednesday), TH (Thursday),
FR (Friday), SA (Saturday), and SU (Sunday).
Once the schedules have been defined, to enable the time scheduling feature, turn on the scheduling
using the
Scheduling OFF
button. It will show that the schedule has been enabled, displaying
Scheduling ON
. At any time, the time scheduling can be disabled by pressing the scheduling activation
button.
In addition, when the scheduler is adjusted and turned on, the scheduling symbol will be displayed
permanently (
) on the home screen of the electronic control screen, indicating that the time schedule
is enabled. To restore manual operation, return to the time scheduling menu and disable the feature
by pressing the
Scheduling ON button.
It will show that the schedule has been disabled, displaying
Scheduling OFF
.
8.3
Service Menu
On the Settings menu (
2
), the electronic control of the
DUAL CLIMA R
pump has a Service Menu,
with which the operation of both the gas circuit and the water circuit can be managed. Any incorrect
setting of any of the parameters in this menu can cause a failure and/or breakage of the machine.
Therefore, most of the parameters of the service menu should only be modified by personnel authorised
by
DOMUSA TEKNIK
. Nevertheless, some technical parameters (described in previous sections) will
be useful for the installer and/or the user and must be adjusted by them, depending on the thermal
and operating characteristics that they wish to obtain in the home.
On this menu, the user can view and modify all technical parameters of the
DUAL CLIMA R
pump..
To exit the menu and return to the home screen, press the touch button.
.
To validate access to the Service Menu, enter the password "2222" and press the "
Ent
" key. Using the
and
buttons, the user can browse through all the technical parameters up to the desired
parameter. By clicking the current value of the parameter, the user can access the screen to modify its
value and validate it by pressing the "
Ent
" key.
NOTE: Any parameters not indicated on the table are technical parameters set at the
factory. Therefore, they should not be modified under any circumstances.
Modifying any of these parameters may cause result in malfunction and/or
breakage of the heat pump.
The following is a list of parameters that can be adjusted by the installer and/or user. Any adjustment
of a parameter that is not in this list may cause a serious breakdown and/or rupture of the heat pump.
Therefore,
DOMUSA TEKNIK
will not be held responsible for damages caused by their incorrect
modification by unauthorised personnel.
Содержание DUAL CLIMA R
Страница 1: ...DUAL CLIMA R Air to Water Heat Pump EN INSTALLATION AND OPERATION INSTRUCTIONS ...
Страница 54: ...EN 54 DUAL CLIMA R 14 2 Dual Clima 6R ...
Страница 55: ...55 DUAL CLIMA R 14 3 Dual Clima 9R ...
Страница 56: ...EN 56 DUAL CLIMA R 14 4 Dual Clima 12R ...
Страница 57: ...57 DUAL CLIMA R 14 5 Dual Clima 16R ...
Страница 58: ...EN 58 DUAL CLIMA R 14 6 Dual Clima 19R ...
Страница 59: ...59 DUAL CLIMA R 14 7 Dual Clima 16RT ...
Страница 60: ...EN 60 DUAL CLIMA R 14 8 Dual Clima 19RT ...
Страница 69: ...69 DUAL CLIMA R DUAL CLIMA 9R ...
Страница 70: ...EN 70 DUAL CLIMA R DUAL CLIMA 12R ...
Страница 71: ...71 DUAL CLIMA R DUAL CLIMA 16R ...
Страница 72: ...EN 72 DUAL CLIMA R DUAL CLIMA 19R ...
Страница 73: ...73 DUAL CLIMA R DUAL CLIMA 16RT ...
Страница 74: ...EN 74 DUAL CLIMA R DUAL CLIMA 19RT ...
Страница 81: ...81 DUAL CLIMA R NOTES ...
Страница 82: ...EN 82 DUAL CLIMA R NOTES ...
Страница 83: ...83 DUAL CLIMA R NOTES ...