Consult with the user before choosing the location of the device. It should not be placed next to
sensitive walls, such as on the wall next to a bedroom. Make sure that the location of the heat pump
is not disruptive to neighbours (sound level, air currents generated, low temperature of the air blown
with risk of freezing plants in the path, etc.).
Choose a location that preferably has sunlight and is protected
from strong and cold winds. If the heat pump is exposed to gusts
of wind that make it possible to overturn it, it should be
supported by suitable guys, as indicated in the figure.
The device must be sufficiently accessible for subsequent
installation and maintenance work. Make sure that the passage of the hydraulic and electrical
connections to the interior of the house is possible and comfortable. The spacing measures indicated
in the figure above are those strictly necessary to ensure correct operation of the device; however,
sometimes, it will be essential to provide more space for maintenance work.
The
DUAL CLIMA R
heat pump is a device specially designed for outdoor installation. Nevertheless,
avoid installing it in a place where it may be exposed to significant water stains or spills (e.g. under a
faulty gutter, near gas outlets, etc.). Move the appliance away from heat sources and flammable
products.
In areas where abundant and copious snowfalls occur, special care must be taken to protect the heat
pump from possible obstructions due to accumulation of snow around it. The obstruction of the air inlet
and/or outlet of the machine due to the accumulation of snow may cause malfunction of the unit and
possible breakdowns. The heat pump must be raised at least 100 millimetres above the maximum
expected snow level. In turn, the roof should be protected from accumulation of snow, by means of a
roof projecting from the building or a similar structure.
6.2
Accessories Supplied
The following accessories are supplied in the interior of the
DUAL CLIMA R
heat pump. Before
proceeding with the installation of the machine, make sure that you receive them and that they are in
good condition.
Documentation:
Inside the machine, open the front door to find the documentation
bag, where all the manuals and documents necessary for the use and installation of
the heat pump are included.
Main board:
It is supplied inside the machine and can be found by removing the
cover of the electronic boards. Before connecting the power supply to the machine,
the control panel should be installed inside the house.
Drain valve:
It is supplied inside the machine, tied with a flange to one leg of the
compressor. This key must be installed in the drain socket on the back of the heat
pump before filling the water in the heating/cooling circuit (see
"Diagrams and
Measurements"
).
4x Anti-vibration dampers:
4 units are supplied in a bag stuck on the back of the
machine, next to the hydraulic outlets.
Содержание DUAL CLIMA R
Страница 1: ...DUAL CLIMA R Air to Water Heat Pump EN INSTALLATION AND OPERATION INSTRUCTIONS ...
Страница 54: ...EN 54 DUAL CLIMA R 14 2 Dual Clima 6R ...
Страница 55: ...55 DUAL CLIMA R 14 3 Dual Clima 9R ...
Страница 56: ...EN 56 DUAL CLIMA R 14 4 Dual Clima 12R ...
Страница 57: ...57 DUAL CLIMA R 14 5 Dual Clima 16R ...
Страница 58: ...EN 58 DUAL CLIMA R 14 6 Dual Clima 19R ...
Страница 59: ...59 DUAL CLIMA R 14 7 Dual Clima 16RT ...
Страница 60: ...EN 60 DUAL CLIMA R 14 8 Dual Clima 19RT ...
Страница 69: ...69 DUAL CLIMA R DUAL CLIMA 9R ...
Страница 70: ...EN 70 DUAL CLIMA R DUAL CLIMA 12R ...
Страница 71: ...71 DUAL CLIMA R DUAL CLIMA 16R ...
Страница 72: ...EN 72 DUAL CLIMA R DUAL CLIMA 19R ...
Страница 73: ...73 DUAL CLIMA R DUAL CLIMA 16RT ...
Страница 74: ...EN 74 DUAL CLIMA R DUAL CLIMA 19RT ...
Страница 81: ...81 DUAL CLIMA R NOTES ...
Страница 82: ...EN 82 DUAL CLIMA R NOTES ...
Страница 83: ...83 DUAL CLIMA R NOTES ...