CT120G Mini Series Inverter 3 Parameter Table
- 14 -
3 Parameter Table
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F00 Group Basic function
F00.00
Motor control
mode
0:speed sensorless vector
control
1:reserved
2:V/F control
2
☆
F00.01
Run command
channel
0: keypad run command
channel (LED off)
1: terminal running command
channel (LED on)
2: 485 run command channel
(LED flickering)
0
○
F00.02
Main frequency
source X
0:Digital setting( pre-set
frequency F00.09,UP/DOWN
change, no power down
memory)
1:Digital setting( pre-set
frequency F00.09,UP/DOWN
change, with power down
memory)
2:AI1
3:AI2
4:keypad potentiometer AI0
5:high speed pulse input(DI5)
6:multi-step speed
7:simple PLC
8:PID
9:485 communication
0
☆
F00.03
Auxiliary frequency
source Y
Same as F00.02main
frequency
0
☆
F00.04
Reference object of
Y frequency source
0: relative to the max.
frequency
1: relative to frequency
source X
0
○
F00.05 Frequency source Unit: frequency source
00
○