CT120G Mini Series Inverter 3 Parameter Table
- 47 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F09.09 reserved
0
~
65535
0
●
F09.10
PID control
deviation limit
0.0%
~
100.0%
0.0
○
F09.11
Feedback loss
detection value
0.0%: not judge feedback loss
0.1%
~
100.0%
0.0
○
F09.12
Feedback loss
detection time
0.0s
~
20.0s
0.0
○
F09.13
PID Differential
limit
0.00%
~
100.00%
0.10
○
F09.14
PID reference
change time
0.00
~
650.00s
0.00
○
F09.15
PID reference filter
time
0.00
~
60.00s
0.00
○
F09.16
PID output filter
time
0.00
~
60.00s
0.00
○
F09.17
Proportional gain
P2
0.0
~
100.0
20.0
○
F09.18 Integral time I2
0.01s
~
10.00s
2.00
○
F09.19
Differential time
D2
0.000s
~
10.000s
0.000
○
F09.20
PID parameter
change term
0:not change
1:DI terminal
2:Automatic change according
to bias
3: Automatic change running
frequency
0
○
F09.21
PID parameter
change bias 1
0.0%
~
F10.22
20.0
○
F09.22
PIDparameter
change bias 2
F10.21
~
100.0%
80.0
○
F09.23 PID initial value
0.0%
~
100.0%
0.0
○
F09.24
PID initial value
keep time
0.00
~
650.00
0.00
○
F09.25 FWD max bias of 0.00
~
100.00%
1.00
○