CT120G Mini Series Inverter 3 Parameter Table
- 54 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F12.05
Data transfer
format selection
Unit position: not standard
MODBUS-RTU protocol
0:not standard
MODBUS-RTU protocol
1:standard MODBUS-RTU
protocol
Ten position:reserved
30
○
F12.06
Communication
read current
resolution
0:0.01A
1:0.1A
0
○
F12.07
Communication
master-slave mode
0:00
0
○
F13 Group Auxiliary function
F13.00 Jogging frequency 0.00Hz
~
max
frequencyF00.06
2.00
○
F13.01
Jogging running
ACC time
0.0s
~
6500.0s
20.0
○
F13.02
Jogging running
DEC time
0.0s
~
6500.0s
20.0
○
F13.03 ACC time 2
0.0s
~
6500.0s
20.0
○
F13.04 DEC time 2
0.0s
~
6500.0s
20.0
○
F13.05 ACC time 3
0.0s
~
6500.0s
20.0
○
F13.06 DEC time 3
0.0s
~
6500.0s
20.0
○
F13.07 ACC time 4
0.0s
~
6500.0s
20.0
○
F13.08 DEC time 4
0.0s
~
6500.0s
20.0
○
F13.09 Jump frequency 1 0.00Hz
~
Max. Frequency
F00.06
0.00
○
F13.10 Jump frequency 2
0.00Hz
~
Max. Frequency
F00.06
0.00
○
F13.11
Jump frequency
range
0.00Hz
~
Max. Frequency
F00.06
0.00
○
F13.12 REV control
0:permit REV 1: forbid REV
0
○
F13.13 Droop control
Slip when the torque current is 0.00
○
Содержание CT120G MINI Series