CT120G Mini Series Inverter 3 Parameter Table
- 25 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F04.15
Proportional gain of
torque regulation
0
~
60000
2000
○
F04.16
Integral gain of
torque regulation 0
~
60000
1300
○
F04.17
Integral attribute of
speed loop
Unit place:integral separation
0: Integral always valid
1: speed loop integral
separation
0
○
F04.18
Vector control
mode weak
magnetic mode
selection
0:no weak magnetic
1:direct calculate
2:Automatic adjust
0
○
F04.19
Over modulation
enable selection
0:forbid
1:enable
0
○
F04.20
Maximum output
voltage coefficient
100%
~
110%
105
☆
F04.21
Maximum torque
coefficient in weak
magnetic region
50%
~
200%
100
○
F04.22
Selection of
generation
(braking) torque
enabling under
speed model
0:disable
1:enable
0
○
F05 Group Keypad and display
F05.00 reserved
0
~
65535
0
●
F05.01
Parameter
initialization
0: no actuation
1: restore default value, not
include motor parameters
2: clear fault records
0
☆
F05.02 reserved
0
~
65535
0
●
F05.03 User password
0
~
65535
0
○
F05.04
Functions of MF
key
0: MF invalid
1:switch between keypad
command and remote
0
☆