CT120G Mini Series Inverter 3 Parameter Table
- 48 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
two output
F09.26
REV max bias of
two output
0.00%
~
100.00%
1.00
○
F09.27
PID Integral
attribute
Unit place: integral attribute 0:
invalid 1: valid
Ten place: output arrive limit,
stop integral or not
0:not stop 1:stop
00
○
F09.28
PID stop
calculation
0: calculate at stop
1: calculate at stop
0
○
F10 Group Wobble, step length and count value
F10.00 Wobble set mode
0
:
Corresponding to centre
frequency
1
:
Corresponding to maximum
frequency
0
○
F10.01 Wobble range
0.0%
~
100.0%
0.0
○
F10.02
Saltation frequency
amplitude
0.0%
~
50.0%
0.0
○
F10.03 Wobble cycle
0.1s
~
3000.0s
10.0
○
F10.04
Wobble triangular
wave rise time
0.1%
~
100.0%
50.0
○
F10.05 Set length
0m
~
65535m
1000
○
F10.06 Actual length
0m
~
65535m
0
○
F10.07 Pulse per meter
,
unit:0.1
0.1
~
6553.5
100.0
○
F10.08 Set count value
1
~
65535
1000
○
F10.09
Designated count
value
1
~
65535
1000
○
F11 Group Multi-step speed and PLC
F11.00
Multi-step speed
command 0
-100.0%
~
100.0%
(
100.0% corresponding to
maximum frquencyF00.06
)
0
○
F11.01 Multi-step speed -100.0%
~
100.0%
0
○