CT120G Mini Series Inverter 3 Parameter Table
- 32 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
F06.25
Curve 3 maximum
input
F06.23
~
10.00V
10.00
○
F06.26
Curve 3 maximum
input corresponding
setting
-100.0%
~
100.0%
100.0
○
F06.27
Keypad
potentiometer AI0
filter time
0.00s
~
10.00s
0.10
○
F06.28
PULSE minimum
input
0.00kHz
~
F06.30
0.00
○
F06.29
PULSE minimum
input corresponding
setting
-100.0%
~
100.0%
0.0
○
F06.30
PULSE maximum
input
F06.28
~
100.00kHz
50.00
○
F06.31
PULSE maximum
input setting
-100.0%
~
100.0%
100.0
○
F06.32 PULSE filt time
0.00s
~
10.00s
0.10
○
F06.33
AI setting curve
selection
Unit place:AI1curve selection
1:curve1(2point,
referF06.13
~
F06.16)
2:curve2(2point,
referF06.18
~
F06.21)
3:curve3(2point,
referF04.23
~
F06.26)
4:curve4(4point,
referA08.00
~
A08.07)
5:curve5
(
4point,
referA08.00
~
A08.15)
Ten place:AI2curveselection,
same as AI1
Hundred place: keypad
potentiometer
AI0curveselection, same as
321
○