CT120G Mini Series Inverter 3 Parameter Table
- 55 -
Function
code
Name
Detailed instruction of
parameters
Default
value
Attribu
-tion
equal to the rated current of
the motor
0.00Hz
~
10.00Hz
F13.14
Set power on arrive
time
0h
~
65535h
0
○
F13.15
Set running arrive
time
0h
~
65535h
0
○
F13.16 Protection selection
0:not protect
1:protect
0
○
F13.17
Frequency
detection
value(FDT1)
0.00Hz
~
max frequency
F00.06
50.00
○
F13.18
Frequency
detection delay
value(FDT1)
0.0%
~
100.0%
(
FDT1 level
)
5.0
○
F13.19
Frequency arrival
detection
amplitude
0.0
~
100.0% (Max.
frequency)
0.0
○
F13.20
Jump frequency
valid or not while
ACC/DEC
0:invalid
1:valid
0
○
F13.21
Running time arrive
action
0:keep running
1: alarm fault
0
○
F13.22
Power on time
arrive action
0:keep running
1: alarm fault
0
○
F13.23
Switch frequency
of ACC time 1/2
0.00Hz
~
Max. Frequency
F00.06
0.00
○
F13.24
Switch frequency
of DEC time 1/2
0.00Hz
~
Max. Frequency
F00.06
0.00
○
F13.25
Terminal JOG
priority
0:invalid
1:valid
0
○
F13.26
Frequency
detection value
(
FDT2
)
0.00Hz
~
Max. Frequency
F00.06
50.00
○