DPC Touch User Manual
29
9.7
Connection of DOGA current control MDC series
DPC
Touch
DOGA MDC series
I/O cable
(DB44 male to DB25 male and DB25 female)
Ref. DOGA: 6-1252006
DB25 I/O port
(potential free)
Input/Output
Assigned signal
pin №
pin
№
Input/Output
Signal
Output 1
Torque Select 1
1
1
Input 1
Preset select 1
Output 2
Torque Select 2
2
2
Input 2
Preset select 2
Output 3
Torque Select 3
3
3
Input 3
Preset select 3
Output 4
Torque Select 4
4
4
Input 4
Preset select 3
Output 5
Tool Disable
4
5
Input 5
Driver Lock
Input 1
D_Motor_Run
5
10
Output 1
Motor Run
Input 2
Tool Alarm
6
11
Output 2
Alarm
Input 3
D_Fastening_OK
7
12
Output 3
Fastening OK
IN_COM
8
22
0V DC
OUT_COM
9
21
24V DC
NOTE:
All 8 inputs and 8 outputs of MDC controller are wired to DPC Touch controller. These signals can be
used for advanced functions (management of Reset, Reverse, etc). I/O’s numbers are matching.
Assign signals on DPC Touch and MDC as above.
Select DC tool interface in DPC Touch operating settings.
Activate Torque selection by binary in DPC Touch operating settings.