DPC Touch User Manual
32
9.10
Connection of Kolver EDU Series tools
DPC
Touch
KOLVER EDU Series
I/O adaptor
(DB44 male to DB9 female and DB25 female)
CN1 port
(10 contacts)
Input/Output
Assigned signal
DB9 pin №
CN1
contact №
Signal
Output 1
1
Output 2
2
Output 3
3
Output 4
Tool Disable
4
4
Stop 5V in
Input 8
D_Fastening_OK
5
6
Torque 24V out
Input 9
D_Motor_Run
6
7
Lever 24V out
Input 10
Tool Alarm
7
8
Error 24V out
IN_COM
8
9
Com 0V DC
OUT_COM
9
1
Com 0V DC
NOTE:
Select DC tool interface in DPC Touch operating settings.
ATTENTION!
Cut the bridges (15)-(35) and (30)-(31) in the DB44 connector of the I/O adaptor
in order to disconnect 24V power supply before making the interface.