DPC Touch User Manual
17
7.
SETTINGS
7.1
Operating
Screen 1 of 4: Management of interface
Parameter
Description
Range
Default
value
Tool selection
Select one of the following option:
-
HDC/SDC
: DOGA Hybrid or Current control tools (HDC30i,
HDC35i, HDC40i, SDC24, SDC40)
-
DC tools
: all electric digital control tools equipped with
24V I/O signals
-
GX, GY, DO, GA
: DOGA low voltage tools (XS-40D, XS-38D,
XT-30D, XS-35D, XT-35D)
-
Other:
special applications on request
-
DC tools
Screws
counting
up/down
This parameter manages counting display. Turn it ON to
count up (1,2,3,…) or OFF to count down (...,3,2,1)
ON/OFF
ON
Screws
counting for
step/job
This parameter manages counting display. Turn it ON to
display counting separately for each step or OFF to display
counting for the whole job.
ON/OFF
ON
Torque
selection by
binary outputs
Selection of tightening presets for each position is done via
Torque selection outputs. These outputs can function in
binary logic or in direct logic (one output per preset).
ON/OFF
ON
Job selection by
binary inputs
Selection of Jobs of DPC Touch can be done via Job
selection inputs. These inputs can function in binary logic
or in direct logic (one input per job).
ON/OFF
ON
Default job
number
Default job is a job which is automatically started after
booting of DPC Touch. If default job number is set to 0,
DPC Touch will not boot any jobs.
NOTE: job selection via inputs has higher priority
0 - 999
1
Screen 2 of 4: Management of buttons in operating mode
Skip button
access without
password
Enables access to Skip button without entering password.
If turned OFF the password will be asked when Skip button
is pressed.
ON/OFF
ON
Back button
access without
password
Enables access to Back button without entering password.
If turned OFF the password will be asked when Back button
is pressed.
ON/OFF
ON
Reset button
access without
password
Enables access to Reset button without entering password.
If turned OFF the password will be asked when Reset
button is pressed.
ON/OFF
ON
Display job
reset button
Job reset button can be displayed or hidden by using this
parameter.
NOTE: if turned OFF and automatic reset is used, then the
current step will be reset instead of the current job.
ON/OFF
ON
Job selection
access without
password
Enables access to Jobs selection without entering
password. If turned OFF the password will be asked when
Job selection button is pressed.
ON/OFF
ON