DPC Touch User Manual
23
8.
OPERATING MODE
Controller is started automatically in Operating mode after booting. Default job is loaded
automatically (see operating settings). Operating mode is accessible through the main menu and
though Job Manager by pressing Load button.
In Operating screen functions are managed in Operating settings.
In operating mode the following error messages can occur:
-
Fastening time is too long/short:
fastening time is out of min/max limits (see programming)
-
Trigger released before torque up:
tool was stopped before reaching torque (see settings)
-
Fastening NG (tool alarm):
fastening NG (alarm) input signal is received from the tool
-
System error:
operating system error (reboot the controller)
-
I/O error:
error of management of inputs and outputs
(check logical and assigned I/O’s)
-
Job complete NG:
job was interrupted or completed with missing screws
2015-12-25 12:05
Job selection button
Previous job button
Job manager button
Next job button
Home button
Last image access button
Position indicators
- Green: Position OK
- Orange: Approaching
- Red: Out of position
Alarm reset button
Step reset button
Job reset button
Next step button
Previous position button
Text message area
Screws counting area
Job/Step progress bar
Fastening status
indicator