Service - 64
SK650 Operator’s Manual
100 Hour
CMW
Check Battery
Check battery every 100 hours. Keep battery and
terminals clean and free of corrosion.
Add distilled water if liquid level is low.
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
NOTICE:
•
Battery gas can explode. Keep sparks and flames away from battery.
•
Always remove negative (-) battery cable first and replace it last.
•
Battery electrolyte is sulfuric acid and poisonous. Will burn skin and cause blindness if splashed into
eyes. Wash hands after working around battery.
•
Never disconnect battery terminals with engine running. Voltage spike may occur and ruin electronic
control modules or other components.
Содержание SK650
Страница 1: ...SK650 Tier 4i Operator s Manual 053 1293 Issue 2 0 Original Translation CMW...
Страница 7: ...Overview 6 SK650 Operator s Manual About This Manual CMW...
Страница 11: ...Contents 10 SK650 Operator s Manual CMW...
Страница 21: ...Safety 20 SK650 Operator s Manual Emergency Procedures CMW...
Страница 38: ...SK650 Operator s Manual Drive 37 CMW Drive Chapter Contents Start Unit 38 Drive 38 Shut Down 40...
Страница 49: ...Transport 48 SK650 Operator s Manual Tow CMW...
Страница 67: ...Service 66 SK650 Operator s Manual 200 Hour CMW Change Hydraulic Filter Change hydraulic filter every 200 hours...
Страница 73: ...Service 72 SK650 Operator s Manual As Needed CMW...
Страница 77: ...Specifications 76 SK650 Operator s Manual Basic Unit CMW...
Страница 80: ......
Страница 81: ......
Страница 82: ...SK650 Operator s Manual Service Record 81 CMW Service Record Service Performed Date Hours...
Страница 83: ...CMW Service Record 82 SK650 Operator s Manual Service Performed Date Hours...