Interpret Diagnostic Codes
CMW
Diagnostic Codes
The following table lists the attributes of each diagnostic code. Information presented includes: code
number, condition causing code to be sent, result, and level of severity.
Code
Condition
Result
Severity
12
normal review mode entry
code is not stored
n/a
13
no 12V power to controller
drill and drive are blocked
essential
14
no 5V power from controller
drill and drive are blocked
essential
15
unknown output driver continuity
problem
code is stored
non-
essential
32
no continuity to shuttle extend
solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
33
no continuity to shuttle retract
solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
34
no continuity to pipe lift solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
35
no continuity to pipe lower solenoid
add pipe or remove pipe is aborted
and code is aborted
non-
essential
42
no continuity to pipe release solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
43
no continuity to lube rear solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
44
no continuity to lube front solenoid
add pipe or remove pipe is aborted
and code is stored
non-
essential
45
no continuity to carriage two speed
solenoid
code is stored
non-
essential
51
no continuity to rotation cw solenoid
cruise control is blocked
essential
52
no continuity to rotation ccw solenoid
cruise control is blocked
essential
53
no continuity to thrust forward
solenoid
cruise control is blocked
essential
54
no continuity to thrust backward
solenoid
cruise control is blocked
essential
55
no continuity to left track forward
solenoid
drive is blocked
essential
61
no continuity to pipe box in solenoid
code is stored
non-
essential
62
no continuity to pipe box out solenoid
code is stored
non-
essential
Содержание JT1220 Mach 1
Страница 1: ...JT1220 Mach 1 Issue 2 1 Operator s Manual 054 114 CMW...
Страница 19: ...Safety 18 JT1220 Mach 1 Operator s Manual Emergency Procedures CMW...
Страница 75: ...Prepare 74 JT1220 Mach 1 Operator s Manual Check Supplies and Prepare Equipment CMW...
Страница 107: ...Conduct a Bore 106 JT1220 Mach 1 Operator s Manual Remove Pullback Device CMW...