Expanding Your System
3.6 RRD42 Compact Disc Expansion Box
%
SCSI ID 4 — open
&
SCSI ID 5 — open
'
SCSI ID 6 — SCSI-A controller
(
SCSI ID 7 — open
SCSI-B
1C1C.0001
V1.3
FFFFFF05 05000001 05000001 05000001 05000001 05000001 FFFFFF03 FFFFFF05
!
"
#
$
%
&
'
(
!
SCSI ID 0 — open
"
SCSI ID 1 — RRD42
#
SCSI ID 2 — RRD42
$
SCSI ID 3 — RRD42
%
SCSI ID 4 — RRD42
&
SCSI ID 5 — RRD42
'
SCSI ID 6 — SCSI-B controller
(
SCSI ID 7 — open
Table 3–1 explains the codes used in the example:
Table 3–1 SCSI Devices Self-Test Status Codes
Status Code
SCSI Device
FFFFFF05
Device is off-line or not installed at this address.
FFFFFF03
SCSI bus controller.
FFFFFFFF
Device not tested—possible SCSI bus controller error.
00000001
External or internal hard disk drive.
05000001
RRD42 compact disc drive.
3.7 Preventive Maintenance
The RRD42 does not require periodic cleaning. To maintain maximum
performance, ensure that the environment where the drive is installed is free
from contamination.
If errors occur, clean the disc with a clean, lint-free cloth. Wipe the disc from
the center out. Do not use solvents, such as benzene, thinner, commercial
cleaners, or antistatic sprays.
3–8