28
Tower
7.4
dTower operation
dTower
R will always be the master module in the blockage. In this module the
controller board is installed
–
it is responsible for controlling the operation of the
blockage.
7.4.1
Controller board
The controller board has the function of controlling user passage, pictogram, sensors,
and all system logic, receiving signals from the access controller board.
7.1.1 Functions
dTower
has many features, some of them customizable through switches DS1 and DS2
located on the controller board.
To program DS1, put each pin in the desired position, according to the table below:
NOTE
-
The grey squares (in bold) in the table above show the standard
configuration, that is, factory settings.
WARNING
To reduce the risk of electric shock, before maintenance, turn off the
power of the equipment by moving the circuit breaker key to the
position OFF. Leave all maintenance services to qualified technical
professionals.
Switch
1
2
3
4
5
6
7
8
Enables sound signal for invasion
ON
Disables sound signal for invasion
OFF
Entry signal for enabling: NO contact
ON
Entry signal for enabling: NC contact
OFF
Allows invasion
ON
Does not allow invasion
OFF
Enables clear access for entry (keep in OFF)
ON
Disables clear access for entry (keep in OFF)
OFF
Enables clear access for exit (keep in OFF)
ON
Disables clear access for exit (keep in OFF)
OFF
Sound alarm 2s before closing
ON
Disables sound alarm 2s before closing
OFF
No maximum time – waits for valid passage
ON ON
Maximum time of 5 seconds
OFF ON
Maximum time of 10 seconds
ON OFF
Maximum time of 15 seconds
OFF OFF
DIP SWITCH DS1