33
a) Passage with or without invasion:
Selection:
DS1-P3 at ON allows invasion, at OFF it does not. This feature defines if, in
standby, the blockage accepts or not the invasion, that is, if it allows or not the obstruction
of its sensors.
If the feature is set not to allow invasion, whenever one of the sensors is obstructed, the
upper pictograms will indicate invasion and the sound signal, if enabled, will beep. In this
case, passage will not be allowed, even if the user is authorized,
On the opposite case, if the feature allows invasion, then no signal will sound and user
validation will proceed normally.
b) Access cleared mode:
Selection:
DS1-P4 and DS1-P5.
The access cleared mode can be used in special events in which it makes sense to keep the
equipment cleared in a certain direction, entry or exit. It can also be used as a test to
check on the door operation. When DS1-P4 is active, the door will open for entry and will
remain thus until disabled. The same happens when DS1-P5 is active, but the door opens
for exit.
By keeping both switches activated, the equipment remains in demo mode, where it
executes continuous movements of opening and closing the doors at intervals of about 4
seconds.
c) Closing sound signal:
Selection:
DS1-P6 at ON.
This function, when activated, emits a continuous beep for two seconds before finalizing
the maximum time for passage and later closing of the door. The selection of maximum
time for passage is defined on DS1-P7 and P8.
d) Maximum time for passage:
Selection:
DS1-P7 and DS1-P8.
This feature defines the maximum accepted time for usage passage. It is possible to
define times of 5s, 10s, 15s, and indefinite (it waits until valid passage occurs).