B.2.8 Normal Operation ................................................................
When the system has been completely configured, a failure in the console’s audio engine will result in an automatic switch to the Redun-
dant Engine. The
Master Audio Outputs Active
button on the Redundant engine will be highlighted in orange and will continue to
process the audio until the operator chooses to switch back to the Main console engine. To do this, simply press the
Master Audio
Outputs Active
button on the Main console and the engine switch will take place.
Assuming that the Main console’s worksurface is functioning then the operator can continue to work normally even if the Redundant
Engine has taken over the audio processing – the two devices are mirrored.
If the Main console’s worksurface is not functioning normally then many console functions can be accessed using the Redundant Engine’s
keyboard, trackball and monitor or any other remote control device in the system.
Example Problem 1:
If power is lost on the main console or its audio engine fails.
Procedure:
The RE will automatically take control of the audio processing and its
Master Audio Outputs Active
button will be highlighted in orange -
the button will not necessarily change colour immediately but will update its status shortly after the switch over of audio processing.
All devices in the system will show a warning message to indicate that the main console has disconnected from the Mirror Group.
Audio can be controlled from a remote control device such as the D5TC or from the RE itself using the keyboard and trackball.
When the main console has been reinstated, the normal boot procedure will take place on power up but the console will boot into a state
where it is independent of the other devices and isolated from the racks. The Consoles and Racks panel will open automatically.
1)
Press the
Mirrored
button in the
Consoles and Racks
panel.
2)
Select the device from the list that you wish to Mirror from (the RE in this example).
3)
Select
FROM other console
and
Mirror Now
and then press
OK -
the console should now be in the same state as the RE.
4)
When you are ready to switch audio processing back to the main console, press the
Master Audio Outputs Active
button on the main
console and it will be highlighted in orange.
Example Problem 2:
If there is a problem on the main console which requires a computer reset.
Procedure:
If the
Reset
button on the rear panel of the main console is pressed, the RE will automatically take control of the audio processing and its
Master Audio Outputs Active
button will be highlighted in orange - the button will not necessarily change colour immediately but will
update its status shortly after the switch over of audio processing.
Alternatively, you may manually switch the audio processing to the RE before pressing the main console
Reset
button. This can be done
using the main console or RE
Master Audio Outputs Active
button
All devices in the system will show a warning message to indicate that the main console has disconnected from the Mirror Group.
Audio can be controlled from a remote control device such as the D5TC or from the RE itself using the keyboard and trackball.
When the main console has been reinstated, the normal boot procedure will take place on power up but the console will boot into a state
where it is independent of the other devices and isolated from the racks. The Consoles and Racks panel will open automatically.
1)
Press the
Mirrored
button in the
Consoles and Racks
panel.
2)
Select the device from the list that you wish to Mirror from (the RE in this example).
3)
Select
FROM other console
and
Mirror Now
and then press
OK -
the console should now be in the same state as the RE.
4)
When you are ready to switch audio processing back to the main console, press the
Master Audio Outputs Active
button and it will
be highlighted in orange.
Example Problem 3:
If there is a problem on the optical fibre loop.
Procedure:
This will depend on the nature of the problem.
A single break in the loop will not affect the sytem at all as the loop's own redundancy will ensure a continuation of normal operation.
However, a red warning light will show in the bottom right corner of the Master Screen and the Optocore Loop light in the System/
Diagnostics panel will go off. A pop up message will also provide a warning.
A serious disturbance in the optical system may result in a switch over to the RE for audio processing but the main console will remain
mirrored and therefore normal operation can continue.
If you wish to switch audio processing back to the main console, press the
Master Audio Outputs Active
button and it will be highlighted
in orange.
Содержание D5T
Страница 1: ...Operation Manual Issue A September 2004 Software Versions 2 4...
Страница 2: ......
Страница 10: ......
Страница 11: ...Chapter 1 1 1 Chapter 1 Getting Started...
Страница 12: ...Chapter 1 1 2...
Страница 32: ...Chapter 2 2 1 Chapter 2 Inputs and Console Channels...
Страница 33: ...Chapter 2 2 2...
Страница 58: ...Chapter 3 3 1 Chapter 3 Busses and Outputs...
Страница 59: ...3 2 Chapter 3...
Страница 68: ...4 1 Chapter 4 Chapter 4 Master Section...
Страница 69: ...Chapter 4 4 2...
Страница 91: ...5 1 Chapter 5 Chapter 5 The Cue List...
Страница 92: ...Chapter 5 5 2...
Страница 111: ...Chapter 6 6 1 Chapter 6 Automation...
Страница 127: ...7 1 Chapter 7 Chapter 7 Effects...
Страница 128: ...7 2 Chapter 7...
Страница 135: ...8 1 Chapter 8 Chapter 8 Troubleshooting...
Страница 136: ...Chapter 8 8 2...
Страница 139: ...A 1 AppendixA Appendix A D5TC Theatre Masters Controller...
Страница 140: ...A 2 Appendix A...
Страница 147: ...B 1 Appendix B Appendix B Multiple Console Setups Inc Redundant Engines...
Страница 148: ...B 2 Appendix B...
Страница 162: ...B 16 Appendix B Standalone PC Screen Appearance...