
20
DC-530 Operation Manual
4.0
Calibration
The DC-530 Counting Scale is a high-precision instrument. Although the scale needs very little maintenance,
you may want to check the calibration after every month or so of normal usage. To do this you will need to have
a test weight of approximately the total capacity of the scale (i.e. a 10 lb weight if you have a 10 lb capacity
scale). After the scale is initially installed, put the weight on the platform and record the weight displayed. Then
every month or so put the same weight on the scale and verify that it still reads the same.
Many facilities have a technician come in and check their units with certified test weights four times a year. If
you are ISO certified, you will want to check to see if your certification specifies more stringent requirements in
order to stay in compliance. Your Rice Lake Weighing Systems scale dealer has the calibrated test weights,
expertise and experience to perform this task for you as well as to check other operating parameters of your scale
and help you effectively integrate scales into your operations. If you do not know who your local Rice Lake
Weighing Systems dealer is, call us at 1-715-736-0002 and we will help you find someone who can provide you
with on-site support.
Follow the instructions below to calibrate your DC-530 scale to ensure its continued accuracy.
NOTE:
You can exit the Maintenance Mode and return to the Counting Mode at any time by pressing the
TARE
key.
1. Ensure that there is no weight on the platter and turn the scale on. It will display the model number and
current firmware version number.
2. With the scale in the Counting Mode, press the
MODE
key to go to the Mode Menu.
3. While at the Mode Menu, press and hold the
REZERO
key while entering
8715
from the numeric
keypad to enter the calibration mode.
4. You can select which scale you are calibrating, Scale 1 or Scale 2, by pressing the
SCALE
key. (If a 2nd
scale is not installed and set in the specifications, pressing the
SCALE
key has no effect.)
5. The scale display will ask you to make sure that there is no weight on the platter then press the
#
[CODE]
key to set the zero point..
6. The scale will briefly flash the message
ZERO POINT SETTING, please WAIT...
Once the zero point is set, the
display returns to the Calibration Screen.. Press the
key to move to the span weight calibration.
The display will change to the following:
7. Place a reference weight on the platform. It is preferable to calibrate the scale using a weight equal to the
All manuals and user guides at all-guides.com