Pag. 47 of 52
- Main parameters description
Name
Displaying
Description
Menu
System protec
-
tion password
System Lock
The system protection password is used to prevent program-
ming modification, or to not allow resetting totalizers.
NB
- write down your password
M47
OCT output pulse
width
OCT Pulse Width
Is possible toset the digital pulse width during the counting.
Range:0.01÷500ms
M54
4÷20mA
output
CL Mode Select
N. 9 selectable analog signal output mode:
4-20mA; 0-20mA; 0-20mA via RS232 (RS485);
4-20mA vs.Sound; 20-4-20mA; 0-4-20mA; 20-0-20mA;
4-20mA vs.Vel.; 4-20mA vs.Energy
M55
4÷20mA output
scale beginning
4mA Output Value
Is the instantaneous flow rate value, expressed in the above
selected measure unit, which is associated with the analog
output scale beginning (4 or 0mA)
M56
4÷20mA output
full scale
VALORE RIF.
A 20 mA
Is the instantaneous flow rate value, expressed in the above
selected measure unit, which is associated with the analog
output full scale (20mA)
M57
Date and Time
YY-MM-DD
HH:MM:SS
Time and date maintaining is secured by an internal battery with life
of about 10 years. In the case where the battery power is exhausted,
turning off the
DIMPU
all the time and date data will be lost.
M60
Digital output
OCT Output Setup
The digital output “OCT” can be set with 26 different functions.
It’s possible to set the digital output to remotely send the totalizer
pulse with option # 24: Flow Rate Pulse
M78
Tab. 11