- Main parameters description
Name
Displaying
Description
Menu
Damping time
Damping
The damping time defines the displayed flow measurement re-
fresh rate in relation to the detected flow measurement variation.
Range: 0÷9990 seconds
M40
Flow velocity
cut-off value
Low Flow Cutoff Val.
When the measured flow velocity is less than the cutoff value, the
display will show the instantaneous flow rate measure at fixed 0.
Range 0.000 ÷ 0.25m/s
M41
Zero flow
calibration
Set Zero
When the fluid in the pipe is stopped, the flow value must be
equal to 0. In case it is not, need to calibrate the Zero flow.
NB
- Make sure that the fluid is perfectly stopped and that the
pipe is full
M42
Correction coef-
ficient
Scale Factor
Coefficient for correcting the measurement accuracy.
Range 0.5 ÷ 1.5%
M45
Tab. 10