02/2014
42 / 72
6159933910
Issue no: 04
CVIR II
5.8.8 - BAR CODe menu
The bar code reader allows you to automatically
select one of the cycles previously programmed in the
controller.
To enable the barcode reader, you need to do the
following:
● Declare the source of selection of the cycles as being
the bar code.
● Configure the serial link:
Barcode function
9,600 bauds
8 data bits
1 stop bit
No parity
They cannot be programmed by the PC.
Set up the table of selection of the cycles according to
the barcode numbers, which can be done only with the
CVIPC2000 software.
As the barcode is read by the controller, it can perform
one of the following actions:
parameter
Comment
No action
No action is performed.
Reset
Reading the code leads to an action
which is identical to the Reset action.
Reset on
NCyCOK
Reading the code leads to a Reset
when the programmed number of
cycles OK is reached.
5.8.9 - CVINet menu
The CVINET software can be used to recover the
tightening results and the curves on PC via Ethernet.
This screen is the configuration of the CVINET data
collector.
parameter
Comment
FIFO blocking
When the result memory to be
transmitted is full, the start cycle that
follows can be locked or not (the start
cycle is not locked on, but next results
are not saved).
Alarm thresh.
When the memory filling rate reaches
this value (1 to 99%), an alarm is
displayed.
Results
Tightening results.
OK curves
Tightening curves with tightening
report = accept.
NOK curves
Tightening curves with tightening
report = reject.
Date synchro
Choose how to update the machine on
time (CVIPC / CVINET / CVIPC and
CVINET).
FIFO capacity
Memory space allocated for not
transmitted results.
FIFO used
Memory space used in the FIFO.
Connection
status
NOK: not connected to the CVINET
server.
OK: connection established.