5.8.3 - etheRNet sOCKet 1 menu
The ethernet socket 1 is used for the following function:
● PC transfer (used to communicate with CVIPC 2000
software).
5.8.4 - etheRNet sOCKet 2 menu
The ethernet socket 2 is used for the following functions:
● CVINET data collector.
● ToolsNet data collector (this choice needs to get a
license).
5.8.5 - etheRNet sOCKet 3 menu
The ethernet socket 3 is used for the following functions:
● Open Protocol (this choice needs to get a license).
● Desoutter Protocol (this choice needs to get a
license).
5.8.6 - pLC menu
To get the functionalities it is necessary to insert an
optional field bus module.
The layout the setting screens shall differ according to
the inserted module.
5.8.6.1 - ethernet/Ip module
parameter
Comment
Ip Address
IP address of the controller in the
PLC network (must differ from
Ethernet address see "ETHERNET
CONFIGURATION menu", page 39).
Mask
In case of integrating the controller in
an existing network, please contact
your administrator to get the correct
mask.
gateway
To be set when the PLC network uses
“Gateway”.