02/2014
15 / 72
6159933910
Issue no: 04
CVIR II
4.2.7 - Control screens
1
2
3
4
02513654
● Press
to display an additional message providing
information on the origin of the fault.
● Press or to move from one screen to another.
>>>
When CVINET or TOOLSNET FIFO
alarm threshold is reached, this symbol is
blinking at the top of the Control screen.
e09
CVINET FIFO is full.
The cycle can not start because the
Locking on when FIFO is full option is
validated and there is no free memory
space left in the FIFO.
Problem with the Ethernet connection or
configuration may be the cause.
e09
CVINET FIFO is full.
The cycle can start but there is no free
memory space left in the FIFO.
Problem with the Ethernet connection or
configuration may be the cause.
screen No. 1
2
6
3
1
5
4
Legend
1 Counter
2 status of the NcyOK counter
3 tightening results
4 Detailed tightening report
5 Min. torque
6 Max. torque
Screen No. 1 displays the tightening results of the last
run cycle (3), the detailed tightening report (4) and the
status of the NcyOK counter (2).
screen No. 2
1
Legend
1 tightening report
Screen No. 2 displays the tightening report (1) : OK or
NOK.
screen No. 3
1
2
Legend
1 status of inputs
2 status of outputs
Provides information on the status of inputs (1) (left-hand
column) and outputs (2) (right-hand column) according to
tightening report.
screen No. 4
02513654
1
Legend
1 Result of a bar code reading
Screen No. 4 displays the result of a bar code reading
(1).