Select the relevant action:
parameter
Comment
unused
The option is disabled.
stop cycle
As soon as one of the torque or angle
parameters is out of tolerances at the
end of one of the phases, the cycle
stops at the end of this phase.
Run reverse
The cycle stops under the same
circumstances as in the Stop Cycle
option, then the tool un-tightens with the
programmed number of rotations.
N.rotat
Number of run reverse rotations
performed by the tool in case of fault
(0-100).
The value 0 causes a run reverse
action which is equal to the number of
rotations performed in the approach
phase if this phase has been
programmed.
Otherwise, the number of rotations is
equal to 0.
Rv speed
Run reverse speed associated with an
action on NOK per cycle or per phase.
thread
Right / Left.
When an action on NOK phase has been
programmed, it will be processed as a priority
with respect to the action on NOK of the cycle.
Run reverse, N.rotat, Rv speed and Thread are
not available in ERPHT mode.
5.3.3.2 - programming cycle parameters for each
cycle
2
3
4
1
5
Legend
1 Nb of cycles OK
2 Report threshold value
3 Control current strategy
4 Results strategy
5 Allowed direction
Select the relevant action:
parameter
Comment
Nb cycles
OK
Number of correct cycles to activate the
NCYOK output
Rep. thr
Torque threshold value to allow to send
a cycle report
Control I
(●) Enabled (Yes ): Torque and current
are evaluated to generate cycle
report.
(
●
) Disabled (No): Only torque is
evaluated to generate cycle report.
Result./
Cycle: Report is generated when cycle
is completed.
Phase: Report is generated any time a
phase is completed.
eRpht Dir.
L: Yes : On pressing trigger, tool starts if
tool selector is set to left direction.
L: No : On pressing trigger, tool does
not start if tool selector is set to left
direction.
R: Yes : On pressing trigger, tool starts
if tool selector is set to right direction.
R: No : On pressing trigger, tool does
not start if tool selector is set to right
direction.