02/2014
27 / 72
6159933910
Issue no: 04
CVIR II
5.3.5.10 - synchro waiting phase
This phase allows you to synchronize the phases of
several controllers. To synchronize several controllers,
you must program a waiting phase for each controller
and use the Synchro signals (see "INPUT / OUTPUT
configuration", page 33).
Principle:
Each controller reports to the others that it has reached
its waiting phase by resetting to 0 the Synchro signal.
Then it waits until the other controllers reach their own
waiting phase by scanning the Synchro input.
1
2
S
S
D
D
F
W
W F
F
Legend
1 Controller n° 1
2 Controller n° 2
In the example, the controller no. 2 runs the beginning
of the cycle (Search Sequence, Run Down Speed), then
waits until the controller no.1 has completed its phases
(Search Sequence, Run Down Speed, Final Speed) to
run together the end of the cycle.
After a 10 s delay (max. time programmed by default),
the controller continues or stops the cycle.
No phase RP.
5.3.5.11 - Disengage phase
Disengage phase is only available in ERPHT
mode.
This phase allows you to release stress in the tool after a
tightening cycle.
You must define each cycle in order to respect at least
following instructions:
● Complete cycle should end by a Disengage phase.
● Action on NOK phase should jump to a Disengage
phase.
1
2
3
4
5
6
Legend
1 Int. time
2 Number of rotation
3 stop time
4 type of rotation
5 Rotation angle or rotation time value
6 Rotational speed
parameter
Comment
Int.time
Time programmed between this phase
and the next one : 0-20 s
Nb rotat.
Number of rotations : 1 - 99
stop time
Time : 0.01 - 20.00 s
Rotat. typ
Strategy to stop the phase : Angle,
Time or Torque
Rot.angl.
Rotation angle : 0 - 30°
Rot.time
Rotation time : 0.01 - 99.90 s
speed
Rotational speed : 0 - 100 %
target t
Torque : 0 - 200 Nm