02/2014
36 / 72
6159933910
Issue no: 04
CVIR II
5.7.4 - Output menu
Outputs
Name
Factory
config.
Comments
Cycle 1
acknowledgement
CyC1
X
Binary coding -weight 1. The cycle acknowledgement is sent back only if
it corresponds to a programmed cycle; otherwise it is at "0".
Cycle 2
acknowledgement
CyC2
X
Binary coding -weight 2. The cycle acknowledgement is sent back only if
it corresponds to a programmed cycle; otherwise it is at "0".
Cycle 4
acknowledgement
CyC4
X
Binary coding -weight 4. The cycle acknowledgement is sent back only if
it corresponds to a programmed cycle; otherwise it is at "0".
Cycle 8
acknowledgement
CyC8
X
Binary coding -weight 8. The cycle acknowledgement is sent back only if
it corresponds to a programmed cycle; otherwise it is at "0".
Cycle 16
acknowledgement
CyC16
Binary coding -weight 16. The cycle acknowledgement is sent back only
if it corresponds to a programmed cycle; otherwise it is at "0".
Ready
ReADy
X
This signal is at "1" when the controller is in working order.
In cycle
INCyC
X
Response to the Start Cycle request. Drops to "0" at end of cycle.
global report OK
ACCRp
X
Sent to the PLC when the cycle is over and the global report is OK.
global report NOK ReJRp
X
Sent to the PLC when the cycle is over and the global report is NOK.
Number of cycles
OK
NCyOK
X
This signal switches to "1" when the number of cycles run with an Accept
report is equal to the programmed number of cycles OK.
For a sequence: at the end of a successful sequence, the output
"Number of cycle OK" =1.
This output is reset after the “RP duration” time set in the
“Station - general parameters” menu.
synchronization
syNC
The synchronization signal falls down at the end of the phase and is
used, connected with synchronization of other controllers to synchronize
the next phase (see "Synchronizing several controllers", page 51).
torque report OK tRQOK
Sent to the PLC when the cycle is over and the torque report is OK.
torque report NOK tRQNOK
Sent to the PLC when the cycle is over and the torque report is NOK.
Angle report OK
ANgOK
Sent to the PLC when the cycle is over and the angle report is OK.
Angle report NOK ANgNOK
Sent to the PLC when the cycle is over and the angle report is NOK.
Maintenance alert MAINt
This signal switches to "1" when maintenance alert is ON. Otherwise, it
is at "0".