29
3.3
Quarterly Inspections
3.3.1
Check Items
Check the items listed in the table below every three months.
Quarterly Inspections Table
No. Check:
Controller
Power
How to check:
Criterion
What to do:
1
Robot base
mounting bolts
OFF
Measure the tightening
torque with a torque
wrench.
No looseness.
Specified torque:
35
7 Nm
Tighten the bolts to the
specified torque.
2
Cooling fan
filters in the
robot controller
OFF
Visually
No dust or dirt.
Clean the cooling fan
filters. (Refer to
Section 3.3.2.)
3.3.2
Cleaning the Air Intake Filter in the Robot Controller
For the cleaning procedures of the air intake filter, refer to the RC7M CONTROLLER
MANUAL, Section 6.4 "Cleaning the Air Intake Filter."