The Stitch Mode Switch (PG10232) is found on the back of the MiniStitcher. (The switch on the
left, looking from the rear of the machine.) There are two stitching modes: single or continuous.
Single stitching is used for production. In the single trip mode only one stitch will be released at a
time, no matter how long the trip switch is activated. With the continuous stitch mode, the machine
will continue to deliver stitches as long as the Foot Switch is activated. The continuous stitch mode
is used only for lubricating, testing and trouble-shooting.
Stitch Mode
The Trip Mode Switch (PG10232) is also found on the back of the MiniStitcher. (The switch on the
right, looking from the rear of the machine.) Either the foot trip or the table trip mode can be
selected even though the standard MiniStitcher comes complete with only a Foot Switch (PG10230).
The Contact Trip (MG10164) can be purchased separately in the IMSK2 Kit and uses the Trip Mode
Switch toggled in the table trip mode.
Be sure that the Foot Switch (PG10230) is plugged into the rear of the MiniStitcher and the Trip
Mode Switch is toggled for this mode before work is begun. The Foot Switch will not activate the
MiniStitcher if the Trip Mode Switch is toggled in the table trip mode.
Trip Mode