Chapter 4 Parameters
|
VFD-VL
4-40
02-02
Multi-Function Input Command 2 (MI2)
Factory
Setting:
2
02-03
Multi-Function Input Command 3 (MI3)
Factory
Setting:
3
02-04
Multi-Function Input Command 4 (MI4)
Factory
Setting:
4
02-05
Multi-Function Input Command 5 (MI5)
Factory
Setting:
0
02-06
Multi-Function Input Command 6 (MI6)
Factory
Setting:
0
02-07
Multi-Function Input Command 7 (MI7)
Factory
Setting:
0
02-08
Multi-Function Input Command 8 (MI8)
When JP1 on the control board is inserted, MI8 functions acc. to Pr02-08.
When JP1 on the control board is removed, MI8 is always "enable", independent of
Pr02-08.
Factory
Setting:
40
Settings
0-43
Control Mode
Settings
VF
VFPG
SVC
FOCPG TQCPG FOCPM
0: no function
○
○
○
○
○
○
1: multi-step speed command 1
○
○
○
○
○
2: multi-step speed command 2
○
○
○
○
○
3: multi-step speed command 3
○
○
○
○
○
4: multi-step speed command 4
○
○
○
○
○
5: Reset
○
○
○
○
○
○
6: JOG command
○
○
○
○
○
7: acceleration/deceleration speed inhibit
○
○
○
○
○
8: the 1st, 2nd
acceleration/deceleration time selection
○
○
○
○
○
9: the 3rd, 4th
acceleration/deceleration time selection
○
○
○
○
○
10: EF input (07-28)
○
○
○
○
○
○
11:
Reserved
12: Stop output
○
○
○
○
○
○
13:
Reserved
14:
Reserved
15: operation speed command form AUI1
○
○
○
○
○
16: operation speed command form ACI
○
○
○
○
○
17: operation speed command form AUI2
○
○
○
○
○
18: Emergency Stop (07-28)
○
○
○
○
○
○
19-23:
Reserved
24: FWD JOG command
○
○
○
○
○
25: REV JOG command
○
○
○
○
○
26:
Reserved
27: ASR1/ASR2 selection
○
○
○
○
○
28: Emergency stop (EF1) (Motor coasts to stop)
○
○
○
○
○
○
29-30:
Reserved
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com