Chapter 4 Parameters
|
VFD-VL
4-58
1 0V
5
1 2 3 4
-1
-2
-3
-4
-5
-1 0V
6 7 8 9
03-00
to
03-02
-6
-7
-8
-9
0
1
2
3
4
4
2
2
4
2
03-09~03-11 gain is positive
4
Z er o bias
Serv e bias as the center, lower than bias = bias
Serv e bias as the center, gr eater than bias=bias
T he absolute value of the bias v oltage
while s er ving as the c enter (unipolar)
Serv e bias as the center (unipolar)
bias
bias
Positiv e bias
Negativ e bias
03-09
Analog Input Gain 1 (AUI1)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 100.0
03-10
Analog Input Gain 1 (ACI)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 100.0
03-11
Analog Input Gain 1 (AUI2)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 100.0
Settings
0.0~500.0%
Parameters 03-03 to 03-11 are used when the source of frequency command is the analog
voltage/current signal.
03-12
Analog Input Delay Time (AUI1)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0.01
03-13
Analog Input Delay Time (ACI)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0.01
03-14
Analog Input Delay Time (AUI2)
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0.01
Settings
0.00 to 2.00 sec
Interferences commonly exist with analog signals, such as those entering AUI, ACI and AUI2.
These interferences constantly affect the stability of analog control and using the Input Noise
Filter will create a more stable system.