In function settings page, you can assign SOC limit, peak cut power, and
BT charge / discharge time interval.
5.3.7 Function Setting
Figure 5-28 : Function Settings page
You can assign the lower limit of battery SOC. Battery will stop discharging
when its SOC reach this limit.
• SOC Limit
Peak cut power is used in peak cut mode. You can assign the peak power of
home load usage from grid. When the home load consumption exceeds this
value, battery will discharge to supply remaining power.
• Peak Cut Power
Time settings can be separated into BT charge time and BT discharge time.
Each setting can set 3 time intervals. These 6 time intervals cannot overlap
with each other.
When the inverter operation mode set to self-consumption or selling first mode,
time settings is enabled. Hybrid inverter will automatically change the mode
to charge first / discharge first in the time intervals you set and return to
self-consumption / selling first mode outside the intervals.
• Time Settings
General Settings
Operation Mode
Function Settings
Install Settings
►
SOC Limit
Peak Cut PWR
Time Settings
►
30%
3kW
BT Charge Time
BT Discharge Time
►
BT Charge Time:
00:00
–
00:00
00:00
–
00:00
00:00
–
00:00
►
BT Charge Time
BT Discharge Time
►
BT Discharge Time:
00:00
–
00:00
00:00
–
00:00
00:00
–
00:00
►
BT Charge Time
BT Discharge Time
ENT
ENT
47