The communication interface between E5 and battery is CAN bus. The physical
connection type is RJ45 socket. To meet the IP65 class, please use the RJ45
connector of E5 accessory.
Figure 4-9
describes the parts of RJ45 connectors.
To assemble the connector, please follow the procedure below:
1. Insert the sealing nut, seals, and support into the cable assembly.
(Cable OD range: 5.0 ~ 6.5 mm.)
2. Connect the sealing nut on the half-finished goods and screw tightly.
(Sealing nut torsion value range: 5~15 kgf-cm)
4.5 CAN Connection
Figure 4-9 : Overview of RJ45 Connectors
Figure 4-10 : Assembling Procedure of RJ45 Connectors
26