E5 can be used in single-phase parallel combination system. In this application,
inverter may be parallel connected to a same AC grid. It recommended connecting
the RS-485, EPO, and digital input together of all E5s for an easily and immediately
remote control. Please refer to
Figure 4-13
,
Figure 4-14
and
Figure 4-15
for the
illustration of multiple inverters combination.
In Australia and New Zealand, the max valid combinations number of E5s is 3.
Please do not install more than 3 E5s at same point of common coupling.
4.10 Multiple inverter combinations
Figure 4-13 : Single-phase parallel combinations
Figure 4-14 : Multiple inverters RS-485 connection
L (Grid)
ID: 1
ID: 2
ID: N
N (Grid)
Data Format:
Baud rate: 9600, 19200 , or 38400
Data bits: 8
Stop bit: 1
Parity: N/A
RS485/USB
or
RS485/RS232
Terminal Resistor
120
Ω
(1/2W)
DATA+ to DATA-
Terminal Resistor
120
Ω
(1/2W)
DATA+ to DATA-
30
Wiring