Type of limit
E5
Total input power
5.5 kW
DC1 / DC2
2.75 kW / 2.75 kW
Table 4-2 : Maximum rating of input power
- The maximum open circuit voltage of PV array should not exceed 600Vdc.
- It is recommended to install an over current protection device between PV
array side and inverter side.
- Any device installed between PV array and inverter must have capability to
withstand the open-circuit voltage and short-circuit current of PV array.
- The input power to the inverter should not higher than the rated power shown
in
Table 4-2
.
CAUTION !
WARNING !
- When undertaking DC wiring, please ensure the correct polarities are connected.
- When undertaking DC wiring please ensures that the power switch on the PV
array is OFF.
Model
Current Rating
Wire size
E5
DC 12A
2 - 3mm
2
/ 14 AWG
Table 4-3 : Cable size
4.3 DC Connection (from PV Array)
Figure 4-7 : DC plug wiring illustration
DC wiring polarities are divided into positive and negative, which is shown in
Figure 4-7
. The connection shall be coherent with the indication marked on
inverter.
PV-KST 4/6
Ⅱ
PV-KBT 4/6
Ⅱ
24
Wiring