When home load consumption exceeds the Peak Cut Power you set in Function
Setting page, battery will discharge to assist the power usage.
5.3.6.2 Peak cut mode
Figure 5-13 : Peak cut mode current flows
Figure 5-14 : Peak cut mode behavior
Electrical Grid
Hybrid Inverter
Battery
Input or
output
Charge or
discharge
Input
Output
Home Load
PV Array
19:00
12:00
07:00
00:00
24:00
PV power
PV power used
for home load consumption
Excess PV power
Home load power usage
Battery discharges
39