ELP AM Series - Manual 2011 - 042011
Copyright Delta UV
©
Page 12
- External interconnecting flexible cords must to be installed in a restricted access location only
accessible by qualified persons.
-
External interconnecting flexible cords must be secured off the floor and to the mechanical
structure.
I15
Please report to the electrical diagram :
annex 2
During maintenance switch off the cabinet
and you can unplug the wires without risk.
24
124
Diagram : Terminal connections on the reactor
I15
24
124
Lug for vessel bonding to
the main earthing ground.
Lugs for vessel bonding
to the equipotential bond.
Equipotential bond.
You may use these lugs to connect exposed dead
metal that may become energized to the rest of the
exposed dead metal around the pool area.
Main earthing ground - Connected
to the supply ground.
The supply ground must be brought in the
junction box by the electrician at the time of
installation from the same point as the supply
conductors.
POOL & ASSOCIATED
METALIC EQUIPMENT