IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT:
Follow the instructions contained herein
EXACTLY
and
IN THE ORDER
LISTED.
Once installed and maintained properly,your UV system will provide years of
successful operation
RECOMMENDATIONS
The reactor must be installed in a technical room,
protected from rain.
The reactor must be installed in a
dry zone
.
The installation zone temperature must be
within 0°C and 40°C.
Ambient humidity must be
< 80%.
Make sure you choose a position where the lamp can be taken out – the
AVAILABLE
HEIGHT should be DOUBLE
the total height of the appliance.
The reactor
must be installed
after the filter(s).
Keep
any sources of hydrochloric
acid vapours away from the installation.
●
Maximum cable length
between the UV reactor and the electrical unit
is
3 meters
.
●
Before accessing the connection terminals, ensure that all supply
circuits are disconnected.
● The reactor installation as a whole must be protected with a
suitably
adapted circuit breaker
.
(See A. Technical characteristics)
● Check that cable complies with legislation and the required power level.
(See A. Technical characteristics)
●Do not use the Delta UV reactor for any other use than that for which it
was designed.