ELP AM Series - Manual 2011 - 042011
Copyright Delta UV
©
Page 8
A. TECHNICAL SPECIFICATIONS
Reactor
EL
P2
10
/3
A
M
EL
P3
10
/3
A
M
EL
P3
14
/3
A
M
EL
P4
14
/3
A
M
EL
P5
14
/3
A
M
EL
P5
16
/3
A
M
EL
P6
16
/3
A
M
EL
P7
16
/3
A
M
EL
P8
16
/3
A
M
EL
P1
01
6/
3A
M
Material
Stainless steel 316 L
Finish
Pickling and passivated
Maximum
pressure
3 bars
Reactor diameter /
length (in)
10 x 39,09 10 x 39,09 14 x 39,09 14 x 39,09 14 x 39,09 16 x 39,09 16 x 39,09 16 x 39,09 16 x 39,09 16 x 39,09
Total Length( in)
46
46
46
46
46
46
46
46
46
46,5
Volume (US
Gallon)
13.95
13.62
23.24
22.91
22.58
30.29
29.96
29.63
29.3
28.64
Connection type
LAP JOINT FLANGE, Stainless steel 316 L
Standard
connection
6 inches
6 inches
8 inches
8 inches
8 inches
8 inches
10 inches
10 inches
12 inches
12 inches
ELECTRICAL UNIT
Type
Painted steel
Dimensions (in)
23.6 x 15.7
x 9.8”
23.6 x 23.6
x 9.8”
23.6 x 23.6
x 9.8”
23.6 x 23.6
x 9.8”
31.5 x 23.6
x 11.8"
31.5 x 23.6
x 11.8"
31.5 x 23.6
x 11.8"
39.4 x 23.6
x 15.7”
39.4 x 23.6
x 15.7”
39.4 x 31.5
x 15.7”
Power supply
230V single
phase
230V single
phase
230V single
phase
230V single
phase
230V single
phase
230V single
phase
230V single
phase
230V single
phase
230V three
phases
230V three
phases
Circuit protector
Ampacity
10 A
10 A
10 A
10 A
10 A
10 A
16 A
16 A
16 A
16 A
Curve of release
of the circuit
breaker
Curve C
Curve C
Curve C
Curve C
Curve C
Curve C
Curve C
Curve C
Curve C
Curve C
Power supply
conductor
60°C copper 2X14 AWG + GROUND
60°C copper 2X12AWG
+ GROUND
60°C copper 3X12AWG
+ GROUND
On / Off switch
Yes
Power indicator light
Yes
UV indicator light
Yes
UV SENSOR
Yes
Temp sensor
Yes
Display
Digital hour c Millenium III
Protection index
IP 54
UV Lamp
Number of lamp
2
3
3
4
5
5
6
7
8
10
Electrical power
594W
891 W
891 W
1188 W
1485 W
1 485 W
1782 W
2 079 W
2376 W
2970 W
Unit UV-C power
85 W
85 W
85 W
85 W
85 W
85 W
85 W
85 W
85 W
85 W
Total UV-C power
170 W
255 W
255 W
340 W
425 W
425 W
510 W
595 W
680 W
850 W
Service life of
lamps
13 000 h
Performances
Flow rate at >40
mJ/cm²
440 gpm
650 gpm
695 gpm
920 gpm
1140 gpm 1260 gpm 1510 gpm 1760 gpm 2010 gpm 2520 gpm
(1) At the end of the lifetime of the lamps, at the most unfavorable point in reactor, for a transmittance of 98%.